Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1990 Jul;2(3):184-90.
doi: 10.1177/104063879000200306.

Comparison of polyacrylamide gel electrophoresis, an enzyme-linked-immunosorbent assay, and an agglutination test for the direct identification of bovine rotavirus from feces and coelectrophoresis of viral RNAs

Affiliations
Comparative Study

Comparison of polyacrylamide gel electrophoresis, an enzyme-linked-immunosorbent assay, and an agglutination test for the direct identification of bovine rotavirus from feces and coelectrophoresis of viral RNAs

S Hammami et al. J Vet Diagn Invest. 1990 Jul.

Erratum in

  • J Vet Diagn Invest 1990 Oct;2(4):355

Abstract

The dsRNA concentrated polyacrylamide gel electrophoresis (CPAGE) detected rotavirus directly from 19% of 77 stool specimens from diarrheic calves. A commercial enzyme-linked immunosorbent assay (ELISA) detected 25%, latex agglutination test, 23%, and polyacrylamide gel electrophoresis (PAGE), 19%. Establishing CPAGE as the "standard," the commercial ELISA and the latex agglutination test both had higher sensitivity (84%) than PAGE (79%). However, PAGE produced the highest specificity (100%), followed by agglutination (88%) and ELISA (84%). The commercial ELISA had a slightly higher sensitivity than agglutination, PAGE, and CPAGE, but the ELISA specificity was generally lower. The latex agglutination test had a lower sensitivity than ELISA, but specificity was higher. Agglutination had similar negative predictive values (94%), compared with agglutination and PAGe, but had the lowest positive predictive value (a measure of accuracy) (70%). Agreement with CPAGE was highest for PAGE (94.8%), followed by agglutination (87%) and ELISA (84.4%). The calculated percentages of total disagreement with all other tests indicated that ELISA differed from the other rotavirus detection assays in 10.4% of the cases, agglutination in 7.8%, PAGE in 2.6%, and CPAGE in 1.3%. The 2 PAGE assays allowed the detection of atypical rotaviruses from feces based on the characteristic "super-short" migration pattern of the 11 genomic segments of rotaviruses and of other members of the Reoviridae.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources