Brain-computer interfaces: an overview of the hardware to record neural signals from the cortex
- PMID: 19660664
- DOI: 10.1016/S0079-6123(09)17521-0
Brain-computer interfaces: an overview of the hardware to record neural signals from the cortex
Abstract
Brain-computer interfaces (BCIs) record neural signals from cortical origin with the objective to control a user interface for communication purposes, a robotic artifact or artificial limb as actuator. One of the key components of such a neuroprosthetic system is the neuro-technical interface itself, the electrode array. In this chapter, different designs and manufacturing techniques will be compared and assessed with respect to scaling and assembling limitations. The overview includes electroencephalogram (EEG) electrodes and epicortical brain-machine interfaces to record local field potentials (LFPs) from the surface of the cortex as well as intracortical needle electrodes that are intended to record single-unit activity. Two exemplary complementary technologies for micromachining of polyimide-based arrays and laser manufacturing of silicone rubber are presented and discussed with respect to spatial resolution, scaling limitations, and system properties. Advanced silicon micromachining technologies have led to highly sophisticated intracortical electrode arrays for fundamental neuroscientific applications. In this chapter, major approaches from the USA and Europe will be introduced and compared concerning complexity, modularity, and reliability. An assessment of the different technological solutions comparable to a strength weaknesses opportunities, and threats (SWOT) analysis might serve as guidance to select the adequate electrode array configuration for each control paradigm and strategy to realize robust, fast, and reliable BCIs.
Similar articles
-
Implantable microscale neural interfaces.Biomed Microdevices. 2007 Dec;9(6):923-38. doi: 10.1007/s10544-006-9045-z. Biomed Microdevices. 2007. PMID: 17252207 Review.
-
Neural prostheses and biomedical microsystems in neurological rehabilitation.Acta Neurochir Suppl. 2007;97(Pt 1):427-34. doi: 10.1007/978-3-211-33079-1_56. Acta Neurochir Suppl. 2007. PMID: 17691406 Review.
-
[Brain-machine interface--current status and future prospects].Brain Nerve. 2010 Feb;62(2):101-11. Brain Nerve. 2010. PMID: 20192030 Review. Japanese.
-
A high-performance brain-computer interface.Nature. 2006 Jul 13;442(7099):195-8. doi: 10.1038/nature04968. Nature. 2006. PMID: 16838020
-
A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array.IEEE Trans Biomed Eng. 1991 Aug;38(8):758-68. doi: 10.1109/10.83588. IEEE Trans Biomed Eng. 1991. PMID: 1937509
Cited by
-
Cognitive rehabilitation in non-communicative brain-damaged patients.Funct Neurol. 2011 Jan-Mar;26(1):55-9. Funct Neurol. 2011. PMID: 21693090 Free PMC article. Review.
-
Sub-meninges implantation reduces immune response to neural implants.J Neurosci Methods. 2013 Apr 15;214(2):119-25. doi: 10.1016/j.jneumeth.2013.01.020. Epub 2013 Jan 28. J Neurosci Methods. 2013. PMID: 23370311 Free PMC article.
-
μ-Foil Polymer Electrode Array for Intracortical Neural Recordings.IEEE J Transl Eng Health Med. 2014 May 29;2:1500207. doi: 10.1109/JTEHM.2014.2326859. eCollection 2014. IEEE J Transl Eng Health Med. 2014. PMID: 27170864 Free PMC article.
-
In vivo monitoring of glial scar proliferation on chronically implanted neural electrodes by fiber optical coherence tomography.Front Neuroeng. 2014 Aug 21;7:34. doi: 10.3389/fneng.2014.00034. eCollection 2014. Front Neuroeng. 2014. PMID: 25191264 Free PMC article.
-
Biomaterials for neuroengineering: applications and challenges.Regen Biomater. 2025 Feb 21;12:rbae137. doi: 10.1093/rb/rbae137. eCollection 2025. Regen Biomater. 2025. PMID: 40007617 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical