Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Aug;29(4):427-30.
doi: 10.1007/s11596-009-0407-7. Epub 2009 Aug 7.

Stereoselective HPLC assay of TJ0711 enantiomers by precolumn derivatization with GITC using UV detection and its application in pharmacokinetics in rats

Affiliations

Stereoselective HPLC assay of TJ0711 enantiomers by precolumn derivatization with GITC using UV detection and its application in pharmacokinetics in rats

Shuping Sun et al. J Huazhong Univ Sci Technolog Med Sci. 2009 Aug.

Abstract

This investigation describes a new precise, sensitive and accurate stereoselective RP-HPLC method for determination of the enantiomers of a novel alpha- and beta-receptor blocking agent, 1-[4-(2-methoxyethyl) phenoxy]-3-[[2-(2- methoxyphenoxy) ethyl]amino]-2-propanol (TJ0711), in rat plasma. GITC was used for precolumn derivatization of TJ0711 enantiomers. Enantiomeric resolution was achieved on a Eurospher-100 C18 column (250 mm x 4.6 mm ID, 5-mum particle size), with UV detection at 255 nm, and the mobile phase consisted of acetonitrile and water (58:42, v/v) containing 0.02% glacial acetic acid (v/v). Using the chromatographic conditions described, TJ0711 enantiomers were well resolved with mean retention time of 10.2 and 11.5 min, respectively. Linear response (r>0.999) was observed over the range of 0.125-12.5 microg/mL of TJ0711 hydrochloride enantiomers. The mean relative standard deviation (RSD%) of the results of within-day precision was < or = 10%. The proposed method was found to be suitable and accurate for the quantitative determination of TJ0711 enantiomers in rat plasma, and it can be used in pharmacokinetic studies.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Pharm Biomed Anal. 2004 Nov 15;36(3):609-15 - PubMed
    1. J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Jun 1;852(1-2):519-28 - PubMed
    1. Anal Biochem. 2003 Apr 15;315(2):262-9 - PubMed
    1. J Chromatogr A. 1998 Dec 18;828(1-2):95-103 - PubMed
    1. Arch Pharm Res. 2000 Feb;23(1):26-30 - PubMed

Publication types

MeSH terms

Substances

LinkOut - more resources