Astigmatic neutrality in biaxial microincision cataract surgery
- PMID: 19683152
- DOI: 10.1016/j.jcrs.2009.03.048
Astigmatic neutrality in biaxial microincision cataract surgery
Abstract
Purpose: To assess the astigmatic effect of biaxial microincision cataract surgery (MICS) with insertion of an UltraChoice 1.0 Rollable Thinlens intraocular lens (IOL) in a sufficiently powered controlled study.
Setting: Queen Elizabeth Hospital, South Australian Institute of Ophthalmology, University of Adelaide, Adelaide, Australia.
Methods: Consecutive patients having biaxial MICS were evaluated prospectively. Keratometry was performed preoperatively and postoperatively. Vector analysis of the alteration in the keratometric cylinder was compared with that in control eyes not having surgery but having keratometry over a similar time frame.
Results: There were 76 eyes in the surgical group and 74 in the control group. The right-hand incision used for IOL insertion had a mean external opening width of 2.00 mm and a mean internal width of 1.89 mm. The left-hand incision measured a mean of 1.49 mm and 1.46 mm, respectively. There was no statistically significant difference between the surgical group and the routine variability in keratometry in the untreated control group in surgically induced astigmatism (surgical group, 0.57 diopter [D] +/- 0.05 [SEM]; control group, 0.54 +/- 0.06 D; P =.660) or the degree of mean calculated flattening effect at the right-hand incision (0.01 +/- 0.06 D and -0.05 +/- 0.05 D, respectively; P = .405) or at the left-hand incision (-0.06 +/- 0.05 D and 0.03 +/- 0.06 D, respectively; P = .283).
Conclusion: Biaxial MICS with insertion of IOL through a temporal incision of 2.0 mm offers prospects of astigmatic neutrality in cataract surgery.
Similar articles
-
Comparison of surgically induced astigmatism after coaxial phacoemulsification through 1.8 mm microincision and bimanual phacoemulsification through 1.7 mm microincision.J Cataract Refract Surg. 2009 Sep;35(9):1563-9. doi: 10.1016/j.jcrs.2009.04.037. J Cataract Refract Surg. 2009. PMID: 19683153
-
Coaxial, microcoaxial, and biaxial microincision cataract surgery: prospective comparative study.J Cataract Refract Surg. 2010 May;36(5):740-6. doi: 10.1016/j.jcrs.2009.11.013. J Cataract Refract Surg. 2010. PMID: 20457364 Clinical Trial.
-
Postoperative corneal shape changes: microincision versus small-incision coaxial cataract surgery.J Cataract Refract Surg. 2009 Feb;35(2):233-9. doi: 10.1016/j.jcrs.2008.10.031. J Cataract Refract Surg. 2009. PMID: 19185236 Clinical Trial.
-
Advances in microincision cataract surgery intraocular lenses.Curr Opin Ophthalmol. 2006 Feb;17(1):80-93. doi: 10.1097/01.icu.0000192520.48411.fa. Curr Opin Ophthalmol. 2006. PMID: 16436929 Review.
-
[Incisions for biaxial and coaxial microincision cataract surgery].Ophthalmologe. 2010 Feb;107(2):108-15. doi: 10.1007/s00347-009-1980-7. Ophthalmologe. 2010. PMID: 20107810 Review. German.
Cited by
-
Toric intraocular lenses: Evidence-based use.Clin Exp Ophthalmol. 2022 Jul;50(5):481-489. doi: 10.1111/ceo.14106. Epub 2022 May 29. Clin Exp Ophthalmol. 2022. PMID: 35584257 Free PMC article. Review.
-
The role of sideport incision in astigmatism change after cataract surgery.Clin Ophthalmol. 2015 Aug 5;9:1421-8. doi: 10.2147/OPTH.S86213. eCollection 2015. Clin Ophthalmol. 2015. PMID: 26346741 Free PMC article.
-
Real-world outcomes of cataract surgeries using a new type of enhanced monofocal toric intraocular lens.Sci Rep. 2024 Nov 12;14(1):27758. doi: 10.1038/s41598-024-65746-2. Sci Rep. 2024. PMID: 39532902 Free PMC article.
-
[MICS - micro incision cataract surgery].Ophthalmologe. 2010 Feb;107(2):105-7. doi: 10.1007/s00347-009-1977-2. Ophthalmologe. 2010. PMID: 20107812 German. No abstract available.
-
Retrospective analysis of cataract surgery outcomes in China from 2009 to 2018: from a national registry system data.BMJ Open. 2023 Apr 5;13(4):e070989. doi: 10.1136/bmjopen-2022-070989. BMJ Open. 2023. PMID: 37019483 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources