MRI gadolinium-based contrast agents. Radiologists beware!
Abstract
Gadolinium (Gd) is used in contrast agents as it enhances magnetic resonance imaging (MRI) signals. To reduce Gd toxicity, it is chelated into linear or macrocyclic complexes. Eight Gd-containing contrast agents have been approved by the European Medicines Agency (EMEA) for use in MRI, and six by the US Food and Drug Administration. Stability depends upon its physicochemical properties. When renal function is normal, the Gd is quickly cleared from the body by the kidneys. For patients with chronic kidney disease, the elimination is greatly reduced and Gd may be released from its chelate and deposit in body tissues, leading to nephrogenic systemic fibrosis (NSF). More than 200 cases of NSF have been reported in the world. NSF is characterized by an extensive fibrosis of skin and tissues, a very severe affection with possible lethal outcome. We propose recommendations to avoid the risk of NSF.
Similar articles
-
Nephrogenic systemic fibrosis: more questions and some answers.Nephron Clin Pract. 2008;110(1):c24-31; discussion c32. doi: 10.1159/000151228. Epub 2008 Aug 7. Nephron Clin Pract. 2008. PMID: 18688172 Review.
-
[Nephrogenic systemic fibrosis].Med Monatsschr Pharm. 2009 Oct;32(10):377-82. Med Monatsschr Pharm. 2009. PMID: 19886227 Review. German.
-
[Nephrogenic systemic fibrosis].G Ital Nefrol. 2008 Jan-Feb;25(1):14-20. G Ital Nefrol. 2008. PMID: 18264914 Review. Italian.
-
Nephrogenic systemic fibrosis associated with gadolinium based contrast agents: a summary of the medical literature reporting.Eur J Radiol. 2008 May;66(2):230-4. doi: 10.1016/j.ejrad.2008.02.011. Epub 2008 Mar 26. Eur J Radiol. 2008. PMID: 18372138 Review.
-
Tissue distribution and kinetics of gadolinium and nephrogenic systemic fibrosis.Eur J Radiol. 2008 May;66(2):200-7. doi: 10.1016/j.ejrad.2008.01.026. Eur J Radiol. 2008. PMID: 18374532 Review.
Cited by
-
Assessing cell-nanoparticle interactions by high content imaging of biocompatible iron oxide nanoparticles as potential contrast agents for magnetic resonance imaging.Sci Rep. 2017 Aug 10;7(1):7850. doi: 10.1038/s41598-017-08092-w. Sci Rep. 2017. PMID: 28798327 Free PMC article.
-
(19)F MRI for quantitative in vivo cell tracking.Trends Biotechnol. 2010 Jul;28(7):363-70. doi: 10.1016/j.tibtech.2010.04.002. Epub 2010 Apr 26. Trends Biotechnol. 2010. PMID: 20427096 Free PMC article. Review.
-
Lanthanide binding and IgG affinity construct: potential applications in solution NMR, MRI, and luminescence microscopy.Protein Sci. 2012 Oct;21(10):1456-66. doi: 10.1002/pro.2133. Epub 2012 Aug 22. Protein Sci. 2012. PMID: 22851279 Free PMC article.