Structural and morphologic evaluation of a novel detergent-enzymatic tissue-engineered tracheal tubular matrix
- PMID: 19698839
- DOI: 10.1016/j.jtcvs.2008.09.085
Structural and morphologic evaluation of a novel detergent-enzymatic tissue-engineered tracheal tubular matrix
Abstract
Objective: We sought to bioengineer a nonimmunogenic tracheal tubular matrix of 6 cm in length and test its structural, functional, and immunologic properties in vitro and in vivo.
Methods: Twelve-centimeter tracheal segments were harvested from Yorkshire boars. Half of each segment was subjected to a detergent-enzymatic method (containing sodium deoxycholate/DNase lavations) of decellularization for as many cycles as needed, and the other half was stored in phosphate-buffered saline at 4 degrees C as a control. Bioengineered and control tracheas were then implanted in major histocompatibility complex-unmatched pigs (allograft) or mice (xenograft) heterotopically for 30 days. Structural and functional analysis and immunostaining were performed after each detergent-enzymatic method cycle and transplantation.
Results: Compared with control tracheas, bioengineered matrices displayed no major histocompatibility complex class I and II antigens after 17 detergent-enzymatic method cycles, without significant (P > .05) differences in their strain ability (rupture force, 56.1 +/- 3.3 vs 55.5 +/- 2.4 N; tissue deformation at 203% +/- 13% vs 200% +/- 8% or 12.2 +/- 0.8 vs 12 +/- 0.5 cm; and applied maximum force, 173.4 +/- 3.2 vs 171.5 +/- 4.6 N). Thirty days after implantation, significantly (P < .01) smaller inflammatory reactions (392 vs 15 macrophages/mm(2) and 874 vs 167 T lymphocytes/mm(2)) and P-selectin expressions (1/6 vs 6/6) were observed in both the xenograft and allograft models with bioengineered matrices compared with those seen with control tracheas. There was no development of anti-pig leukocyte antigen antibodies or increase in both IgM and IgG content in mice implanted with bioengineered tracheas.
Conclusions: Bioengineered tracheal matrices displayed similar structural and mechanical characteristics to native tracheas and excite no immune response to 30 days when implanted as allografts or xenografts. This method holds great promise for the future of tissue-engineered airway replacement.
Similar articles
-
Structural integrity, immunogenicity and biomechanical evaluation of rabbit decelluarized tracheal matrix.J Biomed Mater Res A. 2015 Apr;103(4):1509-19. doi: 10.1002/jbm.a.35273. Epub 2014 Aug 6. J Biomed Mater Res A. 2015. PMID: 25044712
-
Transplantation of the decellularized tracheal allograft in animal model (rabbit).Asian J Surg. 2018 Jul;41(4):328-332. doi: 10.1016/j.asjsur.2017.02.007. Epub 2017 Mar 27. Asian J Surg. 2018. PMID: 28359676
-
Both epithelial cells and mesenchymal stem cell-derived chondrocytes contribute to the survival of tissue-engineered airway transplants in pigs.J Thorac Cardiovasc Surg. 2010 Feb;139(2):437-43. doi: 10.1016/j.jtcvs.2009.10.002. Epub 2009 Dec 7. J Thorac Cardiovasc Surg. 2010. PMID: 19995663
-
Mechanical Evaluation of Tracheal Grafts on Different Scales.Artif Organs. 2018 May;42(5):476-483. doi: 10.1111/aor.13063. Epub 2017 Dec 11. Artif Organs. 2018. PMID: 29226358 Review.
-
Tissue-engineered trachea: History, problems and the future.Eur J Cardiothorac Surg. 2006 Nov;30(5):782-6. doi: 10.1016/j.ejcts.2006.08.023. Epub 2006 Oct 2. Eur J Cardiothorac Surg. 2006. PMID: 17011786 Review.
Cited by
-
Genipin cross-linked decellularized tracheal tubular matrix for tracheal tissue engineering applications.Sci Rep. 2016 Apr 15;6:24429. doi: 10.1038/srep24429. Sci Rep. 2016. PMID: 27080716 Free PMC article.
-
Re: Moving towards in situ tracheal regeneration: the bionic tissue engineered transplantation approach. J. Cell. Mol. Med. Vol. 14, No. 7, 2010, pp. 1877-1889.J Cell Mol Med. 2011 Jan;15(1):24-5. doi: 10.1111/j.1582-4934.2010.01202.x. J Cell Mol Med. 2011. PMID: 21261811 Free PMC article. No abstract available.
-
Double-chamber rotating bioreactor for dynamic perfusion cell seeding of large-segment tracheal allografts: comparison to conventional static methods.Tissue Eng Part C Methods. 2014 Aug;20(8):681-92. doi: 10.1089/ten.TEC.2013.0627. Epub 2014 Mar 5. Tissue Eng Part C Methods. 2014. PMID: 24392662 Free PMC article.
-
Experimental orthotopic transplantation of a tissue-engineered oesophagus in rats.Nat Commun. 2014 Apr 15;5:3562. doi: 10.1038/ncomms4562. Nat Commun. 2014. Retraction in: Nat Commun. 2017 Mar 21;8:15077. doi: 10.1038/ncomms15077. PMID: 24736316 Free PMC article. Retracted.
-
Three-Dimensional Bioprinting of Decellularized Extracellular Matrix-Based Bioinks for Tissue Engineering.Molecules. 2022 May 26;27(11):3442. doi: 10.3390/molecules27113442. Molecules. 2022. PMID: 35684380 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources