An overview of analytical methodologies for the determination of antibiotics in environmental waters
- PMID: 19699391
- DOI: 10.1016/j.aca.2009.07.031
An overview of analytical methodologies for the determination of antibiotics in environmental waters
Abstract
The widespread occurrence of antibiotics as contaminants in the aquatic environment has increased attention in the last years. The concern over the release of antibiotics into the environment is related primarily to the potential for the development of antimicrobial resistance among microorganisms. This article presents an overview of analytical methodologies for the determination of quinolone (Qs) and fluoroquinolone (FQs), macrolide (MLs), tetracycline (TCs), sulfonamide (SAs) antibiotics and trimethoprim (TMP) in different environmental waters. The analysis of these antibiotics has usually been carried out by high-performance liquid chromatography (HPLC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) and to a lesser extent by ultraviolet (UV) or fluorescence detection (FD). A very important step before LC analysis is sample preparation and extraction leading to elimination of interferences and prevention of matrix effect and preconcentration of target analytes.
Similar articles
-
Quantitative determination of trace concentrations of tetracycline and sulfonamide antibiotics in surface water using solid-phase extraction and liquid chromatography/ion trap tandem mass spectrometry.Rapid Commun Mass Spectrom. 2004;18(18):2131-45. doi: 10.1002/rcm.1598. Rapid Commun Mass Spectrom. 2004. PMID: 15317045
-
Analysis of macrolide antibiotics, using liquid chromatography-mass spectrometry, in food, biological and environmental matrices.Mass Spectrom Rev. 2009 Jan-Feb;28(1):50-92. doi: 10.1002/mas.20189. Mass Spectrom Rev. 2009. PMID: 18785191 Review.
-
Simultaneous analysis of 16 sulfonamide and trimethoprim antibiotics in environmental waters by liquid chromatography-electrospray tandem mass spectrometry.J Chromatogr A. 2008 May 9;1190(1-2):390-3. doi: 10.1016/j.chroma.2008.03.057. Epub 2008 Mar 25. J Chromatogr A. 2008. PMID: 18395732
-
Determination of antibiotics in aquatic environment by solid-phase extraction followed by liquid chromatography-electrospray ionization mass spectrometry.J Chromatogr A. 2008 Apr 11;1187(1-2):151-64. doi: 10.1016/j.chroma.2008.02.021. Epub 2008 Feb 12. J Chromatogr A. 2008. PMID: 18295772
-
Analysis of pesticides in water by liquid chromatography-tandem mass spectrometric techniques.Mass Spectrom Rev. 2006 Nov-Dec;25(6):900-16. doi: 10.1002/mas.20093. Mass Spectrom Rev. 2006. PMID: 16705628 Review.
Cited by
-
Removal of Azithromycin from Aqueous Solution Using UV- Light Alone and UV Plus Persulfate (UV/Na2S2O8) Processes.Iran J Pharm Res. 2018;17(Suppl2):54-64. Iran J Pharm Res. 2018. PMID: 31011342 Free PMC article.
-
Toxic influence of key organic soil pollutants on the total flavonoid content in wheat leaves.Water Air Soil Pollut. 2016 Jun;227(6):196. doi: 10.1007/s11270-016-2888-x. Epub 2016 May 25. Water Air Soil Pollut. 2016. PMID: 29386693 Free PMC article.
-
The Ultratrace Determination of Fluoroquinolones in River Water Samples by an Online Solid-Phase Extraction Method Using a Molecularly Imprinted Polymer as a Selective Sorbent.Molecules. 2022 Nov 22;27(23):8120. doi: 10.3390/molecules27238120. Molecules. 2022. PMID: 36500214 Free PMC article.
-
A Universal LC-MS/MS Method for Simultaneous Detection of Antibiotic Residues in Animal and Environmental Samples.Antibiotics (Basel). 2022 Jun 24;11(7):845. doi: 10.3390/antibiotics11070845. Antibiotics (Basel). 2022. PMID: 35884099 Free PMC article.
-
Multifunctional Portable System Based on Digital Images for In-Situ Detecting of Environmental and Food Samples.Molecules. 2023 Mar 8;28(6):2465. doi: 10.3390/molecules28062465. Molecules. 2023. PMID: 36985437 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical