Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2009 Aug;11(4):305-9.

Effect of radiotherapy on the microleakage of adhesive systems

Affiliations
  • PMID: 19701512
Randomized Controlled Trial

Effect of radiotherapy on the microleakage of adhesive systems

Bilinç Bulucu et al. J Adhes Dent. 2009 Aug.

Abstract

Purpose: The aim of this in vitro study was to evaluate the effect of radiotherapy on the microleakage of three adhesive systems: a one-step self-etching, a two-step self-etching, and an etch-and-rinse system.

Materials and methods: Box-shaped Class V cavity preparations were prepared on the buccal surfaces of 84 extracted human molars. The molars were randomly assigned into 6 groups (n = 14) according to the irradiation and adhesive system as follows: G1, Clearfil S3 Bond (irradiated); G2, Clearfil SE Bond (irradiated); G3, Prime & Bond NT (irradiated); G4, Clearfil S3 Bond (nonirradiated); G5, Clearfil SE Bond (nonirradiated); and G6, Prime & Bond NT (nonirradiated). The cavities were restored with composite resin (Filtek Z 250). After restoration of the samples, a total dose of 60 Gy was delivered in 2 Gy/d fractions for 5 days per week for 6 weeks for the related groups. All specimens were thermocycled for 200 cycles between 5 degrees C and 55 degrees C using a dwell time of 60 s in each bath and then placed in 0.5% basic fuchsin solution for 24 h at room temperature. Specimens were then rinsed and sectioned; the dye penetration at the enamel and dentin margins was examined using a stereomicroscope, and a score of 0 to 3 was assigned. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U-tests.

Results: No statistically significant difference existed between the irradiated and nonirradiated groups (p > 0.05). Significant differences in microleakage were observed between enamel and dentin (p < 0.01). The microleakage at the dentin margins was greater than at the enamel margins. Prime & Bond NT revealed statistically significantly (p < 0.05) higher leakage scores in dentin than did ClearfilS3 Bond and Clearfil SE Bond.

Conclusion: Within the limitations of this study, irradiation application did not affect the microleakage of dental adhesive systems.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources