Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Oct;36(7):711-9.
doi: 10.1016/j.nucmedbio.2009.06.001. Epub 2009 Jul 29.

Reproducibility of the kinetic analysis of 3'-deoxy-3'-[(18)F]fluorothymidine positron emission tomography in mouse tumor models

Affiliations

Reproducibility of the kinetic analysis of 3'-deoxy-3'-[(18)F]fluorothymidine positron emission tomography in mouse tumor models

Seung Jin Choi et al. Nucl Med Biol. 2009 Oct.

Abstract

Objectives: We assessed the reproducibility of the kinetic analysis of 3'-deoxy-3'-[(18)F]fluorothymidine (FLT) positron emission tomography (PET) in A431 human epidermoid carcinoma and murine Lewis lung carcinoma (LLC) tumor models.

Methods: We injected 7.4 MBq of FLT (n=10 for each group) and acquired 2-h dynamic PET images. A second scan was performed 1 day later. We calculated standardized uptake value (SUV), kinetic rate constants, volume of distribution of phosphorylated FLT (V(dm)), net influx constant (K(FLT-CA)) and influx constant by Patlak graphical analysis (K(FLT-PA)). The percent difference between measurements of a parameter was calculated to compare the reproducibilities of different parameters.

Results: FLT phosphorylation was higher in mice with A431 tumors than in mice with LLC tumors (P<.005). Differences in the standard deviations of the percent differences of parameters were statistically significant (P<.001) in each model. In mice with A431 tumors, SUV, V(dm), K(FLT-CA) and K(FLT-PA) had standard deviations of the percent difference of < or = 20%. The most reproducible parameter was K(FLT-PA), although the standard deviation (15.6%) was not statistically different from those of V(dm) (15.8%), K(FLT-CA) (17.5%) and SUV (18.9%). In mice with LLC tumors, K(1), K(1)/k(2) and k(3) had standard deviations of the percent difference of < or = 20%. No macroparameters reflecting a total FLT flux had standard deviations of < or = 20%.

Conclusion: Our results show the reproducibility of the kinetic macroparameters of FLT PET in mouse tumors with high FLT phosphorylation.

PubMed Disclaimer

Publication types

LinkOut - more resources