Measurements of neutron distribution in neutrons-gamma-rays mixed field using imaging plate for neutron capture therapy
- PMID: 19726204
- DOI: 10.1016/j.apradiso.2009.08.002
Measurements of neutron distribution in neutrons-gamma-rays mixed field using imaging plate for neutron capture therapy
Abstract
The imaging plate (IP) technique is tried to be used as a handy method to measure the spatial neutron distribution via the (157)Gd(n,gamma)(158)Gd reaction for neutron capture therapy (NCT). For this purpose, IP is set in a water phantom and irradiated in a mixed field of neutrons and gamma-rays. The Hiroshima University Radiobiological Research Accelerator is utilized for this experiment. The neutrons are moderated with 20-cm-thick D(2)O to obtain suitable neutron field for NCT. The signal for IP doped with Gd as a neutron-response enhancer is subtracted with its contribution by gamma-rays, which was estimated using IP without Gd. The gamma-ray response of Gd-doped IP to non-Gd IP is set at 1.34, the value measured for (60)Co gamma-rays, in estimating the gamma-ray contribution to Gd-doped IP signal. Then measured distribution of the (157)Gd(n,gamma)(158)Gd reaction rate agrees within 10% with the calculated value based on the method that has already been validated for its reproducibility of Au activation. However, the evaluated distribution of the (157)Gd(n,gamma)(158)Gd reaction rate is so sensitive to gamma-ray energy, e.g. the discrepancy of the (157)Gd(n,gamma)(158)Gd reaction rate between measurement and calculation becomes 30% for the photon energy change from 33keV to 1.253MeV.
Similar articles
-
Development of monitoring method of spatial neutron distribution in neutrons-gamma rays mixed field using imaging plate for NCT--depression of the field.Appl Radiat Isot. 2011 Dec;69(12):1885-7. doi: 10.1016/j.apradiso.2011.02.050. Epub 2011 Mar 8. Appl Radiat Isot. 2011. PMID: 21439837
-
Feasibility study on using imaging plates to estimate thermal neutron fluence in neutron-gamma mixed fields.Radiat Prot Dosimetry. 2011 Nov;147(3):394-400. doi: 10.1093/rpd/ncq493. Epub 2010 Dec 31. Radiat Prot Dosimetry. 2011. PMID: 21196463
-
Combination of boron and gadolinium compounds for neutron capture therapy. An in vitro study.J Exp Clin Cancer Res. 2005 Mar;24(1):93-8. J Exp Clin Cancer Res. 2005. PMID: 15943038
-
A fast response and gamma-insensitive neutron detector based on parallel-plate avalanche counter.Radiat Prot Dosimetry. 2008;129(4):426-30. doi: 10.1093/rpd/ncm462. Epub 2007 Nov 11. Radiat Prot Dosimetry. 2008. PMID: 17998200 Review.
-
Neutron cross-sections for next generation reactors: new data from n_TOF.Appl Radiat Isot. 2010 Apr-May;68(4-5):643-6. doi: 10.1016/j.apradiso.2010.01.003. Epub 2010 Jan 11. Appl Radiat Isot. 2010. PMID: 20096595 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources