Radiation safety in fluoroscopy for neuraxial injections
- PMID: 19731844
Radiation safety in fluoroscopy for neuraxial injections
Abstract
Certified Registered Nurse Anesthetists (CRNAs) perform epidural steroid injections for chronic back and extremity pain. Placing epidural needles using fluoroscopy and confirming the needle placement by epidurogram has been suggested as a means to increase the efficacy of epidural injections while decreasing complications. Because of the risk of radiation injury to patients and staff when using fluoroscopy, the purpose of this article is to review the concepts of fluoroscopy and radiation safety for CRNAs. Following a literature search using keywords such as fluoroscopy, radiation injury, and radiation safety, relevant articles were identified. In addition, the reference lists of these articles were reviewed to identify other pertinent sources regarding this topic. The risks of stochastic and deterministic effects from radiation exposure necessitate the need for practitioners who are knowledgeable in equipment, patient, and procedure related factors that influence radiation exposure. Practitioner conduct, using the as-low-as-reasonably achievable (ALARA) principle, results in choices regarding these factors that minimize the time and intensity of radiation exposure to patients, anesthesia providers, and staff.
Similar articles
-
The ALARA (as low as reasonably achievable) concept in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients--a white paper executive summary.Pediatr Radiol. 2006 Sep;36 Suppl 2(Suppl 2):110-2. doi: 10.1007/s00247-006-0184-4. Pediatr Radiol. 2006. PMID: 16862422 Free PMC article. No abstract available.
-
The ALARA concept in pediatric cardiac catheterization: techniques and tactics for managing radiation dose.Pediatr Radiol. 2006 Sep;36 Suppl 2(Suppl 2):146-53. doi: 10.1007/s00247-006-0194-2. Pediatr Radiol. 2006. PMID: 16862415 Free PMC article. Review.
-
Management of pediatric radiation dose using Philips fluoroscopy systems DoseWise: perfect image, perfect sense.Pediatr Radiol. 2006 Sep;36 Suppl 2(Suppl 2):216-20. doi: 10.1007/s00247-006-0216-0. Pediatr Radiol. 2006. PMID: 16862406 Free PMC article. Review.
-
Prevention of radiation injury from medical imaging.J Vasc Surg. 2011 Jan;53(1 Suppl):22S-27S. doi: 10.1016/j.jvs.2010.05.139. Epub 2010 Sep 16. J Vasc Surg. 2011. PMID: 20843625
-
ALARA in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients--a white paper executive summary.J Am Coll Radiol. 2006 Sep;3(9):686-8. doi: 10.1016/j.jacr.2006.04.008. J Am Coll Radiol. 2006. PMID: 17412149
Cited by
-
Radiation safety for pain physicians: principles and recommendations.Korean J Pain. 2022 Apr 1;35(2):129-139. doi: 10.3344/kjp.2022.35.2.129. Korean J Pain. 2022. PMID: 35354676 Free PMC article. Review.
-
The Radiation Exposure of Radiographer Related to the Location in C-arm Fluoroscopy-guided Pain Interventions.Korean J Pain. 2014 Apr;27(2):162-7. doi: 10.3344/kjp.2014.27.2.162. Epub 2014 Mar 28. Korean J Pain. 2014. PMID: 24748945 Free PMC article.
-
Comparison of radiation exposure during fluoroscopy-guided transforaminal epidural steroid injections at different vertebral levels.Korean J Radiol. 2015 Mar-Apr;16(2):357-62. doi: 10.3348/kjr.2015.16.2.357. Epub 2015 Feb 27. Korean J Radiol. 2015. PMID: 25741198 Free PMC article.
-
How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?Korean J Pain. 2014 Apr;27(2):145-51. doi: 10.3344/kjp.2014.27.2.145. Epub 2014 Mar 28. Korean J Pain. 2014. PMID: 24748943 Free PMC article.
-
A Randomized Controlled Trial about the Levels of Radiation Exposure Depends on the Use of Collimation C-arm Fluoroscopic-guided Medial Branch Block.Korean J Pain. 2013 Apr;26(2):148-53. doi: 10.3344/kjp.2013.26.2.148. Epub 2013 Apr 3. Korean J Pain. 2013. PMID: 23614076 Free PMC article.