Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Nov;93(2):322-30.
doi: 10.1016/j.radonc.2009.08.014. Epub 2009 Sep 11.

MRI-guided treatment-planning optimisation in intracavitary or combined intracavitary/interstitial PDR brachytherapy using tandem ovoid applicators in locally advanced cervical cancer

Affiliations

MRI-guided treatment-planning optimisation in intracavitary or combined intracavitary/interstitial PDR brachytherapy using tandem ovoid applicators in locally advanced cervical cancer

Ina M Jürgenliemk-Schulz et al. Radiother Oncol. 2009 Nov.

Abstract

Purpose: To study the impact of MRI-guided treatment planning on dose/volume parameters in pulsed dose rate (PDR) brachytherapy (BT) for cervical cancer. Additionally, we investigated the potential benefit of an intracavitary/interstitial (IC/IS) modification of the classical tandem ovoid applicator.

Material and methods: For 24 patients we compared Standard PDR BT plans, Scaled Standard plans and MRI-guided Optimised plans. The total EBRT/BT prescribed dose to Manchester point A or to 90% of the HR-CTV (D90 HR-CTV) expressed in EQD(2) was 80 Gy(alphabeta10) in 17 patients (Period I) and 84 Gy(alphabeta10) in 7 patients (Period II). The constraints to 2 cm(3) of the OAR were 90 Gy(alphabeta3) for bladder and 75 Gy(alphabeta3) for rectum, sigmoid and bowel. Most cases were treated with a traditional intracavitary tandem ovoid applicator. In 6 patients we used a newly designed combined IC/IS modification for the second PDR fraction and investigated the benefit of the interstitial part.

Results: The average gain of MRI-guided optimisation expressed in D90 HR-CTV was 4+/-9 Gy(alphabeta10) (p<0.001) and 10+/-7 Gy(alphabeta10) (p=0.003) in the two periods. The dose to 2 cm(3) of the OAR met the constraints. In the group that was treated with the combined IC/IS approach, we could increase the D90 HR-CTV for the second PDR fraction with 5.4+/-4.2 Gy(alphabeta10) (p=0.005) and the D100 with 4.8+/-3.1 Gy(alphabeta10) (p=0.07).

Conclusions: Three-dimensional MRI-guided treatment planning and optimisation improves the DVH parameters compared to conventional planning strategies. Additional improvement can be achieved by using a combined IC/IS approach.

PubMed Disclaimer

MeSH terms