Middle ear implantable hearing devices: an overview
- PMID: 19762429
- PMCID: PMC4111438
- DOI: 10.1177/1084713809346262
Middle ear implantable hearing devices: an overview
Abstract
Hearing loss affects approximately 30 million people in the United States. It has been estimated that only approximately 20% of people with hearing loss significant enough to warrant amplification actually seek assistance for amplification. A significant interest in middle ear implants has emerged over the years to facilitate patients who are noncompliant with conventional hearing aides, do not receive significant benefit from conventional aides, or are not candidates for cochlear implants. From the initial studies in the 1930s, the technology has greatly evolved over the years with a wide array of devices and mechanisms employed in the development of implantable middle ear hearing devices. Currently, these devices are generally available in two broad categories: partially or totally implantable using either piezoelectric or electromagnetic systems. The authors present an up-to-date overview of the major implantable middle ear devices. Although the current devices are largely in their infancy, indications for middle ear implants are ever evolving as promising studies show good results. The totally implantable devices provide the user freedom from the social and practical difficulties of using conventional amplification.
Figures
References
-
- Barbara M., Manni V., Monini S. (2009). Totally implantable middle ear device for rehabilitation of sensorineural hearing loss: Preliminary experience with the Esteem, Envoy. Acta Otolaryngolgy, 129, 429–432 - PubMed
-
- Beltrame A. M., Martini A., Prosser S., Giarbini N., Streitberger C. (2009). Coupling the Vibrant Soundbridge to cochlea round window: Auditory results in patients with mixed hearing loss. Otology & Neurotology, 30, 194–201 - PubMed
-
- Cremers C. W., Verhaegen V. J., Snik A. F. (2009). The floating mass transducer of the Vibrant Soundbridge interposed between the stapes and tympanic membrane after incus necrosis. Otology & Neurotology, 30, 76–78 - PubMed
-
- Dyer R. K., Jr., Dormer K. J., Hough J. V., Nakmali U., Wickersham R. (2002). Biomechanical influences of magnetic resonance imaging on the SOUNDTEC Direct System implant. Otolaryngology—Head and Neck Surgery, 127, 520–530 - PubMed
-
- Falcone M. T., Kaylie D. M., Labadie R. F., Haynes D. S. (2008). Bone-anchored hearing aid abutment skin overgrowth reduction with clobetasol. Otolaryngology—Head and Neck Surgery, 139, 829–832 - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources