Comparative Study
. 2009 Nov;40(11):3499-503.
doi: 10.1161/STROKEAHA.109.556035. Epub 2009 Sep 17.

Noninvasive detection of vertebral artery stenosis: a comparison of contrast-enhanced MR angiography, CT angiography, and ultrasound

Affiliations
Comparative Study

Noninvasive detection of vertebral artery stenosis: a comparison of contrast-enhanced MR angiography, CT angiography, and ultrasound

Sofia Khan et al. Stroke. 2009 Nov.

Abstract

Background and purpose: Vertebral stenosis is associated with a high risk of recurrent stroke, but noninvasive imaging techniques to identify it have lacked sensitivity. Contrast-enhanced MR angiography and CT angiography have been recently developed and appear to have better sensitivity. However, no prospective studies have compared both of these techniques with ultrasound against the gold standard of intra-arterial angiography in the same group of patients.

Methods: Forty-six patients were prospectively recruited in whom intra-arterial angiography was being performed. Contrast-enhanced MR angiography, CT angiography, and duplex ultrasound were also performed. Angiographic images were analyzed blinded to patient identity by 2 experienced neuroradiologists.

Results: Contrast-enhanced MR angiography had the highest sensitivity and specificity (Radiologist 1, 0.83 and 0.91, respectively; Radiologist 2, 0.89 and 0.87) for detecting >or=50% stenosis. CT angiography had good sensitivity (Radiologist 1, 0.68; Radiologist 2, 0.58) and excellent specificity (Radiologist 1, 0.92; Radiologist 2, 0.93), whereas duplex had low sensitivity (0.44) but excellent specificity (0.95). For vertebral origin stenosis >or=50%, sensitivities were similar for contrast-enhanced MR angiography (Radiologist 1, 0.91; Radiologist 2, 0.82) but relatively higher for CT angiography (Radiologist 1, 0.82; Radiologist 2, 0.82) and duplex (0.67).

Conclusions: Contrast-enhanced MR angiography is the most sensitive noninvasive technique to detect vertebral artery stenosis and also has high specificity. CT angiography has good sensitivity and high specificity. In contrast, ultrasound has low sensitivity and will miss many vertebral stenoses.

PubMed Disclaimer

Publication types