Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Practice Guideline
. 2009 Aug;11(2):221-7.
doi: 10.3171/2009.3.SPINE08719.

Radiographic assessment of cervical subaxial fusion

Affiliations
Practice Guideline

Radiographic assessment of cervical subaxial fusion

Michael G Kaiser et al. J Neurosurg Spine. 2009 Aug.

Abstract

Object: The objective of this systematic review was to use evidence-based medicine to identify the best methodology for radiographic assessment of cervical subaxial fusion.

Methods: The National Library of Medicine and Cochrane Database were queried using MeSH headings and keywords relevant to cervical fusion. Abstracts were reviewed and studies meeting inclusion criteria were selected. The guidelines group assembled an evidentiary table summarizing the quality of evidence (Classes I-III). Disagreements regarding the level of evidence were resolved through an expert consensus conference. The group formulated recommendations that contained the degree of strength based on the Scottish Intercollegiate Guidelines network. Validation was done through peer review by the Joint Guidelines Committee of the American Association of Neurological Surgeons/Congress of Neurological Surgeons.

Results: Pseudarthrosis is best assessed through the absence of motion detected between the spinous processes on dynamic radiographs (Class II). The measurement of interspinous distance on dynamic radiographs of >or= 2 mm is a more reliable indicator for pseudarthrosis than angular motion of 2 degrees based on Cobb angle measurements (Class II). Similarly, it is also understood that the pseudarthrosis rate will increase as the threshold for allowable motion on dynamic radiographs decreases. The combination of interspinous distance measurements and identification of bone trabeculation is unreliable when performed by the treating surgeon (Class II). Identification of bone trabeculation on static radiographs should be considered a less reliable indicator of cervical arthrodesis than dynamic films (Class III).

Conclusions: Consideration should be given to dynamic radiographs and interspinous distance when assessing for pseudarthrosis.

PubMed Disclaimer

Publication types

LinkOut - more resources