Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Oct 15;81(20):8441-6.
doi: 10.1021/ac9014269.

Simultaneous and label-free determination of wild-type and mutant p53 at a single surface plasmon resonance chip preimmobilized with consensus DNA and monoclonal antibody

Affiliations

Simultaneous and label-free determination of wild-type and mutant p53 at a single surface plasmon resonance chip preimmobilized with consensus DNA and monoclonal antibody

Yongcan Wang et al. Anal Chem. .

Abstract

Simultaneous determination of wild-type and total p53 proteins (wild-type and mutant combined) present in cancer cell lysates has been performed with a dual-channel surface plasmon resonance (SPR) instrument. To achieve specificity, each channel of the SPR chip was modified with a consensus double-stranded (ds-) DNA and a monoclonal antibody. The high affinity of the consensus ds-DNA to the wild-type p53 and the antibody to total p53 results in remarkably low detection levels (10.6 and 1.06 pM for the wild-type and total p53, respectively). The difference between the SPR signals reveals the extent of p53 mutation, which is indicative of cancer development. The SPR signals increase with the p53 concentration across a wide range (from low picomolar to nanomolar levels) that amply encompasses the typical cellular p53 concentrations. The applicability of the method to real sample analysis has been demonstrated with the comparative analyses of normal and cancer cell lysates. The normal cell samples all displayed significantly higher levels of wild-type p53. In contrast, elevated levels of mutant p53 were observed from the cancer cell lysates. In comparison with enzyme-linked immunosorbant assay (ELISA), SPR obviates the need of a second antibody labeled with an enzyme in the "sandwich enzyme immunoassay" format and is capable of real-time monitoring of the binding events. Thus, SPR could potentially serve as an attractive technique for rapid, sensitive, reliable, and label-free cancer diagnoses.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources