Diurnal variation of corneal biomechanics and intraocular pressure in normal subjects
- PMID: 19787600
- DOI: 10.1177/112067210901900518
Diurnal variation of corneal biomechanics and intraocular pressure in normal subjects
Abstract
Purpose: To assess and investigate the relationship between diurnal variations in intraocular pressure (IOP) and biomechanical properties of cornea.
Methods: Sixty-two healthy volunteers were recruited. Corneal compensated IOP (IOPcc), Goldmann-correlated IOP (IOPg), corneal resistance factor (CRF), and corneal hysteresis (CH) parameters were recorded by the Ocular Response Analyzer (ORA). Central corneal thickness (CCT) was measured using an ultrasonic pachymeter. Three consecutive measurements of IOPcc, IOPg, CRF, CH, and CCT were recorded at 8:00 am, 11:00 am, 2:00 pm, and 5:00 pm. One-way analysis of variance and Pearson correlation tests were used for statistical analysis. Intra device repeatability was evaluated using Scheffe multiple comparison.
Results: IOPcc, IOPg, CRF, CH, and CCT measurements displayed a stable profile during daytime acquisitions and no statistically significant variation was noted (p>0.05). All measurements of IOPcc, IOPg, CRF, and CH recorded by ORA at 8:00 am, 11:00 am, 2:00 pm, and 5:00 pm were all found to be highly repeatable (p>0.05). There was a statistically significant and inverse correlation between IOPcc and CH (p=0.001), and a positive correlation was detected between IOPcc and CRF (p=0.001). CRF and CH were both found to be positively correlated to CCT (p=0.001).
Conclusions: IOPcc readings and recordings of corneal biomechanics were constant throughout the day in healthy eyes. CRF and CH seem to exert different effects on IOPcc as diverse correlations were detected between CRF, CH, and IOPcc. Assessment of IOP and corneal biomechanics using ORA was found to be a highly repeatable.
Similar articles
-
Diurnal variation of ocular hysteresis, corneal thickness, and intraocular pressure.Optom Vis Sci. 2008 Dec;85(12):1185-92. doi: 10.1097/OPX.0b013e31818e8abe. Optom Vis Sci. 2008. PMID: 19050473
-
Intraocular pressure and biomechanical corneal properties measure by ocular response analyser in patients with primary congenital glaucoma.Acta Ophthalmol. 2016 Aug;94(5):e293-7. doi: 10.1111/aos.12912. Epub 2015 Dec 9. Acta Ophthalmol. 2016. PMID: 26647905
-
Impact of dehydration and fasting on intraocular pressure and corneal biomechanics measured by the Ocular Response Analyzer.Int Ophthalmol. 2018 Apr;38(2):451-457. doi: 10.1007/s10792-017-0479-5. Epub 2017 Mar 2. Int Ophthalmol. 2018. PMID: 28255839
-
Comparison of Corneal Biomechanics Between Low and High Myopic Eyes-A Meta-analysis.Am J Ophthalmol. 2019 Nov;207:419-425. doi: 10.1016/j.ajo.2019.07.007. Epub 2019 Jul 30. Am J Ophthalmol. 2019. PMID: 31374186
-
Changes in corneal biomechanics in patients with diabetes mellitus: a systematic review and meta-analysis.Acta Diabetol. 2020 Aug;57(8):973-981. doi: 10.1007/s00592-020-01481-0. Epub 2020 Mar 22. Acta Diabetol. 2020. PMID: 32201905
Cited by
-
Reproducibility of ocular response analyzer measurements and their correlation with central corneal thickness.Graefes Arch Clin Exp Ophthalmol. 2010 Nov;248(11):1617-22. doi: 10.1007/s00417-010-1471-1. Epub 2010 Aug 10. Graefes Arch Clin Exp Ophthalmol. 2010. PMID: 20697730
-
Diurnal variation in central corneal thickness and intraocular pressure in eyes with pseudoexfoliation syndrome without glaucoma.Indian J Ophthalmol. 2014 Nov;62(11):1072-1076. doi: 10.4103/0301-4738.146755. Indian J Ophthalmol. 2014. PMID: 25494249 Free PMC article.
-
Corneal biomechanics in different age groups.Int Ophthalmol. 2020 Apr;40(4):967-974. doi: 10.1007/s10792-019-01273-8. Epub 2020 Jan 8. Int Ophthalmol. 2020. PMID: 31916064
-
Corneal and intraocular pressure changes associated to the circadian rhythms: a narrative review.Int J Ophthalmol. 2024 Oct 18;17(10):1921-1928. doi: 10.18240/ijo.2024.10.20. eCollection 2024. Int J Ophthalmol. 2024. PMID: 39430020 Free PMC article. Review.
-
Instability of 24-hour intraocular pressure fluctuation in healthy young subjects: a prospective, cross-sectional study.BMC Ophthalmol. 2014 Nov 4;14:127. doi: 10.1186/1471-2415-14-127. BMC Ophthalmol. 2014. PMID: 25370361 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources