Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Jan;38(1):288-91.
doi: 10.1097/CCM.0b013e3181b42e13.

Predicting dead space ventilation in critically ill patients using clinically available data

Affiliations
Comparative Study

Predicting dead space ventilation in critically ill patients using clinically available data

David C Frankenfield et al. Crit Care Med. 2010 Jan.

Abstract

Objective: To develop and validate an equation to predict dead space to tidal volume ratio (Vd/Vt) from clinically available data in critically ill mechanically ventilated patients.

Design: Prospective, observational study using a convenience sample of patients whose arterial blood gas and respiratory gas exchange had been measured with indirect calorimetry.

Setting: Medical and surgical critical care units of a university medical center.

Patients: Adult, mechanically ventilated patients at rest with Fio2 < or =0.60 and no air leaks who had recent arterial blood gas recordings and end-tidal carbon dioxide concentration monitoring.

Interventions: Observational only.

Measurements and main results: Indirect calorimetry was used to determine carbon dioxide production and expired minute ventilation in 135 patients. Tidal volume and respiratory rate were recorded from the ventilator. End tidal carbon dioxide concentration, body temperature, arterial carbon dioxide partial pressure (Paco2), and other clinical data were recorded. Vd/Vt was calculated using the Enghoff modification of the Bohr equation (Paco2 - PECO2/Paco2). Regression analysis was then used to construct a predictive equation for Vd/Vt using the clinical data: Vd/Vt = 0.32 + 0.0106 (Paco2 - ETCO2) + 0.003 (RR) + 0.0015 (age) (R = 0.67). A second group of 50 patients was measured using the same protocol and their data were used to validate the equations developed from the original 135 patients. The equation was found to be unbiased and precise.

Conclusions: Vd/Vt is predictable from clinically available data. Whether this predicted quantity is valuable clinically must still be determined.

PubMed Disclaimer

Comment in

MeSH terms

LinkOut - more resources