The effects of lubricant eye drops on visual function as measured by the Inter-blink interval Visual Acuity Decay test
- PMID: 19789659
- PMCID: PMC2754081
- DOI: 10.2147/opth.s6225
The effects of lubricant eye drops on visual function as measured by the Inter-blink interval Visual Acuity Decay test
Abstract
Objective: The purpose of the current study was to evaluate the effects of two marketed ocular lubricants on the visual decay in dry eye patients using the Inter-blink interval Visual Acuity Decay (IVAD) test.
Methods: This controlled, randomized, double-masked crossover study compared the effects of a polyethylene glycol/propylene glycol-based (PEG/PG) tear and a carboxymethylcellulose sodium (CMC)/glycerin tear on the visual acuity decay between blinks of dry eye patients. At visit 1 (Day 0), baseline IVAD measurements were recorded prior to instillation of a single drop of randomized study medication. IVAD testing was repeated at 15-, 45-, and 90-minutes post-instillation. Reading rate and functional blink rate were also evaluated. At the second visit (Day 7 +/- 3), study procedures were repeated using crossover treatment.
Results: Forty-eight (48) subjects with dry eye (61.1 +/- 14.8 years old, 79.2% female, 95.8% white) completed the study. Treatment with the PEG/PG-based tear demonstrated statistically significantly longer time to one-line loss of best-corrected visual acuity (BCVA) as determined by the IVAD test at 90 minutes post-instillation compared to the CMC/glycerin tear (P = 0.0365). Measurements of median time at BCVA, reading rate, and functional blink rate were similar for both treatments. Both formulations were well tolerated in the population studied.
Conclusions: Treatment with the PEG/PG-based tear demonstrated statistically significant improved maintenance of visual acuity between blinks at 90 minutes post-instillation compared to the CMC/glycerin tear. This is the first study to demonstrate the ability of an artificial tear to extend visual acuity maintenance between blinks, as measured by the IVAD test.
Keywords: artificial tears; dry eye; ocular lubricant; visual function.
Figures
References
-
- Walker P, Ousler GW, III, Workman DA, et al. Visual function in normals compared to patients diagnosed with dry eye as measured by the inter-blink interval acuity decay (IVAD) test Invest Ophthalmol Vis Sci 200748E-abstract 422.
-
- Abelson MB, Doane MG, Ousler G. Tear film and blink dynamics. In: Albert DM, Miller JW, Azar DT, Blodi BA, editors. Principles and Practice of Ophthalmology. Philadelphia: WB Saunders Co; 2008.
-
- Abelson MB, Lamberts DW, editors. Dry Eye Update. Princeton, NJ: Excerpta Medica; 1983.
-
- Bron AJ. Diagnosis of dry eye. Surv Ophthalmol. 2001;45(Suppl 2):S221–S226. - PubMed
-
- Ousler GW, III, Wilcox Hagberg K, Schindelar M, et al. The ocular protection index. Cornea. 2008;27(5):509–513. - PubMed
LinkOut - more resources
Full Text Sources
