Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Mar;21(3):231-5.
doi: 10.1111/j.1540-8167.2009.01609.x. Epub 2009 Oct 5.

Are MADIT II criteria for implantable cardioverter defibrillator implantation appropriate for Chinese patients?

Affiliations

Are MADIT II criteria for implantable cardioverter defibrillator implantation appropriate for Chinese patients?

Chung-Wah Siu et al. J Cardiovasc Electrophysiol. 2010 Mar.

Abstract

Background: MADIT-II demonstrated that prophylactic implantation of an implantable cardioverter-defibrillator (ICD) device prevents sudden cardiac death (SCD) in patients with myocardial infarction (MI) and impaired left ventricular ejection fraction (LVEF). It remains unclear whether the MADIT-II criteria for ICD implantation are appropriate for Chinese patients.

Methods and results: We compared the clinical characteristics and outcome for a cohort of consecutive Chinese patients who satisfied MADIT-II criteria for ICD implantation with the original published MADIT-II population. Seventy consecutive patients who satisfied MADIT-II criteria but did not undergo ICD implantation (age: 67 years, male: 77%) were studied. Their baseline demographics were comparable with the original MADIT-II cohort with the exception of a higher incidence of diabetes mellitus. After follow-up of 35 months, most deaths (78%) were due to cardiac causes (72% due to SCD). The 2-year SCD rate (10.0%) was comparable with that of the MADIT-II conventional group (12.1%), but higher than the MADIT-II defibrillator group (4.9%). Similarly, the 2-year non-SCD rate was 3.0%, also comparable with the MADIT-II conventional group (4.6%), but lower than the MADIT-II defibrillator group (7.0%). Cox regression analysis revealed that advance NYHA function class (Hazard Ratio [HR]: 3.5, 95% Confidence Interval [CI]: 1.48-8.24, P = 0.004) and the lack of statin therapy (HR: 3.7, 95%CI: 1.35-10.17, P = 0.011) were independent predictors for mortality in the MADIT-II eligible patients.

Conclusion: Chinese patients who satisfy MADIT-II criteria for ICD implantation are at similar risk of SCD and non-SCD as the original MADIT-II subjects. Implantation of an ICD in Chinese patients is appropriate.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources