Influence of the organic layer thickness in (metal-assisted) secondary ion mass spectrometry using Ga+ and C60+ projectiles
- PMID: 19811931
- DOI: 10.1016/j.jasms.2009.08.022
Influence of the organic layer thickness in (metal-assisted) secondary ion mass spectrometry using Ga+ and C60+ projectiles
Abstract
This article investigates the influence of the organic film thickness on the characteristic and molecular ion yields of polystyrene (PS), in combination with two different substrates (Si, Au) or gold condensation (MetA-SIMS), and for atomic (Ga+) and polyatomic (C60+) projectile bombardment. PS oligomer (m/z approximately 2000 Da) layers were prepared with various thicknesses ranging from 1 up to 45 nm on both substrates. Pristine samples on Si were also metallized by evaporating gold with three different thicknesses (0.5, 2, and 6 nm). Secondary ion mass spectrometry was performed using 12 keV atomic Ga+ and C60+ projectiles. The results show that upon Ga+ bombardment, the yield of the fingerprint fragment C7H7+ increases as the PS coverage increases and reaches its maximum for a thickness that corresponds to a complete monolayer (approximately 3.5 nm). Beyond the maximum, the yields decrease strongly and become constant for layers thicker than 12 nm. In contrast, upon C60+ bombardment, the C7H7+ yields increase up to the monolayer coverage and they remain constant for higher thicknesses. A strong yield enhancement is confirmed upon Ga+ analysis of gold-metallized layers but yields decrease continuously with the gold coverage for C60+ bombardment. Upon Ga+ bombardment, the maximum PS fingerprint ion yields are obtained using a monolayer spin-coated on gold, whereas for C60+, the best results are obtained with at least one monolayer, irrespective of the substrate and without any other treatment. The different behaviors are tentatively explained by arguments involving the different energy deposition mechanisms of both projectiles.
Similar articles
-
Effects of metal nanoparticles on the secondary ion yields of a model alkane molecule upon atomic and polyatomic projectiles in secondary ion mass spectrometry.Anal Chem. 2008 Aug 15;80(16):6235-44. doi: 10.1021/ac800568y. Epub 2008 Jul 17. Anal Chem. 2008. PMID: 18630928
-
Metal-assisted secondary ion mass spectrometry using atomic (Ga+, In+) and fullerene projectiles.Anal Chem. 2007 May 15;79(10):3673-89. doi: 10.1021/ac062406l. Epub 2007 Apr 7. Anal Chem. 2007. PMID: 17417819
-
Use of monoatomic and polyatomic projectiles for the characterisation of polylactic acid by static secondary ion mass spectrometry.Rapid Commun Mass Spectrom. 2005;19(18):2517-27. doi: 10.1002/rcm.2089. Rapid Commun Mass Spectrom. 2005. PMID: 16106345
-
Energetic ion bombardment of Ag surfaces by C60+ and Ga+ projectiles.J Am Soc Mass Spectrom. 2005 Oct;16(10):1677-86. doi: 10.1016/j.jasms.2005.06.009. J Am Soc Mass Spectrom. 2005. PMID: 16099165
-
Structure and dynamics in self-organized C60 fullerenes.J Nanosci Nanotechnol. 2007 Apr-May;7(4-5):1111-50. doi: 10.1166/jnn.2007.303. J Nanosci Nanotechnol. 2007. PMID: 17450883 Review.
Cited by
-
Single Cell Profiling Using Ionic Liquid Matrix-Enhanced Secondary Ion Mass Spectrometry for Neuronal Cell Type Differentiation.Anal Chem. 2017 Mar 7;89(5):3078-3086. doi: 10.1021/acs.analchem.6b04819. Epub 2017 Feb 10. Anal Chem. 2017. PMID: 28194949 Free PMC article.
-
Organic secondary ion mass spectrometry: signal enhancement by water vapor injection.J Am Soc Mass Spectrom. 2010 Dec;21(12):2005-10. doi: 10.1016/j.jasms.2010.08.013. Epub 2010 Aug 27. J Am Soc Mass Spectrom. 2010. PMID: 20864353
References
LinkOut - more resources
Full Text Sources