Minimum variance beamforming combined with adaptive coherence weighting applied to medical ultrasound imaging
- PMID: 19811995
- DOI: 10.1109/TUFFC.2009.1268
Minimum variance beamforming combined with adaptive coherence weighting applied to medical ultrasound imaging
Abstract
Currently, the nonadaptive delay-and-sum (DAS) beamformer is used in medical ultrasound imaging. However, due to its data-independent nature, DAS leads to images with limited resolution and contrast. In this paper, an adaptive minimum variance (MV)-based beamformer that combines the MV and coherence factor (CF) weighting is introduced and adapted to medical ultrasound imaging. MV-adaptive beamformers can improve the image quality in terms of resolution and sidelobes by suppressing off-axis signals, while keeping onaxis ones. In addition, CF weighting can improve contrast and sidelobes by emphasizing the in-phase signals and reducing the out-of-phase ones. Combining MV and CF weighting results in simultaneous improvement of imaging resolution and contrast, outperforming both DAS and MV beamformers. In addition, because of the power of CF in reducing the focusing errors, the proposed method presents satisfactory robustness against sound velocity inhomogeneities, outperforming the regularized MV beamformer. The excellent performance of the proposed beamforming approach is demonstrated by several simulated examples.
Similar articles
-
Adaptive beamforming applied to medical ultrasound imaging.IEEE Trans Ultrason Ferroelectr Freq Control. 2007 Aug;54(8):1606-13. IEEE Trans Ultrason Ferroelectr Freq Control. 2007. PMID: 17703664
-
Eigenspace-based minimum variance beamforming applied to medical ultrasound imaging.IEEE Trans Ultrason Ferroelectr Freq Control. 2010 Nov;57(11):2381-90. doi: 10.1109/TUFFC.2010.1706. IEEE Trans Ultrason Ferroelectr Freq Control. 2010. PMID: 21041127
-
Combined phase screen aberration correction and minimum variance beamforming in medical ultrasound.Ultrasonics. 2017 Mar;75:71-79. doi: 10.1016/j.ultras.2016.11.015. Epub 2016 Nov 25. Ultrasonics. 2017. PMID: 27939788
-
Detection of Point Scatterers in Medical Ultrasound.IEEE Trans Ultrason Ferroelectr Freq Control. 2022 Feb;69(2):617-628. doi: 10.1109/TUFFC.2021.3129619. Epub 2022 Jan 27. IEEE Trans Ultrason Ferroelectr Freq Control. 2022. PMID: 34797764 Review.
-
Use of modulated excitation signals in medical ultrasound. Part II: Design and performance for medical imaging applications.IEEE Trans Ultrason Ferroelectr Freq Control. 2005 Feb;52(2):192-207. doi: 10.1109/tuffc.2005.1406546. IEEE Trans Ultrason Ferroelectr Freq Control. 2005. PMID: 15801308 Review.
Cited by
-
Visualizing the movement of the contact between vocal folds during vibration by using array-based transmission ultrasonic glottography.J Acoust Soc Am. 2017 May;141(5):3312. doi: 10.1121/1.4983472. J Acoust Soc Am. 2017. PMID: 28599522 Free PMC article.
-
Separation of mainlobe and sidelobe contributions to B-mode ultrasound images based on the aperture spectrum.J Med Imaging (Bellingham). 2022 Nov;9(6):067001. doi: 10.1117/1.JMI.9.6.067001. Epub 2022 Nov 1. J Med Imaging (Bellingham). 2022. PMID: 36337381 Free PMC article.
-
A Robust Method for Ultrasound Beamforming in the Presence of Off-Axis Clutter and Sound Speed Variation.Ultrasonics. 2018 Sep;89:34-45. doi: 10.1016/j.ultras.2018.04.011. Epub 2018 Apr 25. Ultrasonics. 2018. PMID: 29723842 Free PMC article.
-
Weighted Capon beamformer combined with coded excitation in ultrasound imaging.J Med Ultrason (2001). 2015 Oct;42(4):477-88. doi: 10.1007/s10396-015-0640-6. Epub 2015 Jul 28. J Med Ultrason (2001). 2015. PMID: 26576972
-
Amplitude and phase estimator combined with the Wiener postfilter for medical ultrasound imaging.J Med Ultrason (2001). 2016 Jan;43(1):11-8. doi: 10.1007/s10396-015-0671-z. Epub 2015 Oct 5. J Med Ultrason (2001). 2016. PMID: 26703162
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources