Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Sep;14(3):233-9.
doi: 10.1007/s11325-009-0305-z. Epub 2009 Oct 9.

Validation of ECG-derived sleep architecture and ventilation in sleep apnea and chronic fatigue syndrome

Affiliations
Comparative Study

Validation of ECG-derived sleep architecture and ventilation in sleep apnea and chronic fatigue syndrome

Michael J Decker et al. Sleep Breath. 2010 Sep.

Abstract

Purpose: Newly developed algorithms putatively derive measures of sleep, wakefulness, and respiratory disturbance index (RDI) through detailed analysis of heart rate variability (HRV). Here, we establish levels of agreement for one such algorithm through comparative analysis of HRV-derived values of sleep-wake architecture and RDI with those calculated from manually scored polysomnographic (PSG) recordings.

Methods: Archived PSG data collected from 234 subjects who participated in a 3-day, 2-night study characterizing polysomnographic traits of chronic fatigue syndrome were scored manually. The electrocardiogram and pulse oximetry channels were scored separately with a novel scoring algorithm to derive values for wakefulness, sleep architecture, and RDI.

Results: Four hundred fifty-four whole-night PSG recordings were acquired, of which, 410 were technically acceptable. Comparative analyses demonstrated no difference for total minutes of sleep, wake, NREM, REM, nor sleep efficiency generated through manual scoring with those derived through HRV analyses. When NREM sleep was further partitioned into slow-wave sleep (stages 3-4) and light sleep (stages 1-2), values calculated through manual scoring differed significantly from those derived through HRV analyses. Levels of agreement between RDIs derived through the two methods revealed an R = 0.89. The Bland-Altman approach for determining levels of agreement between RDIs generated through manual scoring with those derived through HRV analysis revealed a mean difference of -0.7 +/- 8.8 (mean +/- two standard deviations).

Conclusion: We found no difference between values of wakefulness, sleep, NREM, REM sleep, and RDI calculated from manually scored PSG recordings with those derived through analyses of HRV.

PubMed Disclaimer

References

    1. Lancet. 1986 Feb 8;1(8476):307-10 - PubMed
    1. Cardiol Clin. 1992 Aug;10(3):499-537 - PubMed
    1. BMC Neurol. 2007 Dec 05;7:40 - PubMed
    1. Sleep. 2008 Aug;31(8):1071-8 - PubMed
    1. Chest. 2003 Mar;123(3):695-703 - PubMed

LinkOut - more resources