Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2009 Oct 7:(4):CD003531.
doi: 10.1002/14651858.CD003531.pub3.

Pressure modification for improving usage of continuous positive airway pressure machines in adults with obstructive sleep apnoea

Affiliations
Meta-Analysis

Pressure modification for improving usage of continuous positive airway pressure machines in adults with obstructive sleep apnoea

Ian Smith et al. Cochrane Database Syst Rev. .

Update in

Abstract

Background: Continuous Positive Airways Pressure (CPAP) is considered to be the cornerstone of therapy for obstructive sleep apnoea (OSA). However, compliance with this treatment is frequently poor, which may lead to ongoing symptoms of sleep disruption, daytime sleepiness and poor waking cognitive function. Mechanical interventions which involve changing the way that positive pressure is delivered, and the addition of humidification, might improve compliance.

Objectives: To determine the efficacy of pressure level modifications and additional humidification in increasing CPAP machine usage.

Search strategy: We searched the Cochrane Airways Group Specialised Register (September 2008).

Selection criteria: Randomised controlled trials (RCTs) assessing interventions to improve compliance with CPAP usage. Control groups received fixed pressure CPAP.

Data collection and analysis: Two authors assessed articles for inclusion in the review and extracted data. We made attempts to obtain additional unpublished data from the trialists.

Main results: Forty-five studies met the inclusion criteria (1874 participants). Auto-CPAP (30 studies, 1136 participants): a statistically significant difference in machine usage of 0.21 hours/night (0.08 to 0.35) was observed in favour of auto-CPAP from cross-over studies. This difference is of questionable clinical significance. Pooled effect estimates from parallel group trials detected a similar sized difference for average nightly machine usage, but this was not statistically significant. Evidence from parallel group studies did not identify a statistically significant difference between pressure modes in Epworth Sleepiness Scores, but there was an overall reduction of 0.64 units with cross-over studies (-0.12 to -1.16) in favour of auto-CPAP. Parallel group studies did not identify a significant difference. More participants preferred auto-CPAP to fixed CPAP where this was measured. Bi-level PAP (six studies, 285 participants): no significant differences were observed in machine usage. One small study found no difference in preference. C-Flex (six studies, 318 participants): no significant difference was observed in machine usage. Humidification (three studies, 135 participants): there were conflicting findings between the studies. Two parallel group trials found no significant difference in machine usage, whereas a cross-over study found a significant difference.

Authors' conclusions: Improvement in average machine use of auto-CPAP was superior in studies with a cross-over design; the point estimate in parallel group trials was similar, but did not reach statistical significance. It is uncertain how use of machines in study settings relates to 'real world' use. Where preference was measured participants preferred auto-CPAP to fixed pressure CPAP. Further studies are required to assess the evidence for Bi-PAP, C-Flex(TM) and humidification. The studies assembled were characterised by high machine usage in the control groups, and low withdrawal rates. Future studies need to consider the effects of treatment in participants with more mild disease, and those who struggle to accept therapy despite persistent symptoms.

PubMed Disclaimer

Update of

Similar articles

Cited by

LinkOut - more resources