Assessing the clinical or pharmaco-economical benefit of target controlled desflurane delivery in surgical patients using the Zeus anaesthesia machine

Affiliations
Free article
Randomized Controlled Trial

Assessing the clinical or pharmaco-economical benefit of target controlled desflurane delivery in surgical patients using the Zeus anaesthesia machine

B Lortat-Jacob et al. Anaesthesia. 2009 Nov.
Free article

Abstract

The Zeus anaesthesia machine includes an auto-control mode which allows targeting of end-tidal volatile and inspired oxygen concentrations. We assessed the clinical benefits and economic impact of this target-controlled anaesthesia compared with conventional manually controlled anaesthesia. Eighty patients were randomly assigned to receive desflurane either with a fresh gas flow set by the anaesthetist or in auto-control mode. Drug delivery was adjusted to maintain bispectral index between 40-60 units and systolic arterial pressure under 15 mmHg above its pre-induction value (upper limit) and over 90 mmHg (lower limit). Blood pressure was maintained in the desired range for 89% and 91% of the maintenance period for auto-control and manual control respectively (p = 0.49). Bispectral index was in the desired range for 82% and 79% of the maintenance period, for auto-control and manual control respectively (p = 0.46). Oxygen consumption was more than halved by the use of auto-control mode, and mean (SD) desflurane consumption during surgery was 0.07 (0.04) vs 0.2 (0.07) ml.min(-1) in auto-control and manual control respectively (p < 0.0001). The number of drug delivery adjustments per hour was significantly lower in auto-control mode (mean (SD) 7 (2) vs 15 (12); p < 0.0001). Thus, the auto-control mode provided similar haemodynamic stability and bispectral control as did conventional manually controlled anaesthesia, but led to a reduction in gas and vapour consumption with a more clinically acceptable workload.