Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Jan;30(1):112-6.
doi: 10.1097/IAE.0b013e3181b32ebf.

Twenty-three-gauge and 20-gauge vitrectomy in epiretinal membrane surgery

Affiliations
Comparative Study

Twenty-three-gauge and 20-gauge vitrectomy in epiretinal membrane surgery

Anton Haas et al. Retina. 2010 Jan.

Abstract

Purpose: The purpose of this study was to investigate the safety profile of the 23-gauge sutureless vitrectomy system in the treatment of epiretinal membranes compared with standard 20-gauge vitrectomy.

Methods: A retrospective case comparison of 20-gauge and 23-gauge vitrectomy performed in 167 and 64 eyes, respectively, by the same surgeon. Intraoperative and postoperative complications, duration of surgery, and postoperative visual acuity results were evaluated.

Results: Postoperative hypotony occurred significantly more often in the 23-gauge group [9.4% (n = 6) vs. 0% (n = 0), P < 0.001]. With the 23-gauge system, the incidence of retinal detachment was 1.6% (n = 1), vitreous hemorrhage was 0%, and endophthalmitis was 1.6% (n = 1). Patients with 20-gauge vitrectomy developed retinal detachments in 1.8% (n = 3), vitreous hemorrhages in 1.2% (n = 2), and endophthalmitis in 2.4% (n = 4). The mean overall duration of surgery was significantly shorter in the 23-gauge procedures with 23.1 +/- 6.5 minutes compared with 34.5 +/- 9.1 minutes in the 20-gauge procedures (P < 0.05). At postoperative Day 2, patients with 23-gauge vitrectomy regained preoperative mean best-corrected visual acuity of 20/60. Patients who had 20-gauge vitrectomy experienced a statistically significant decrease of visual acuity from 20/80 to 20/100 (P < 0.05).

Conclusion: Twenty-three-gauge vitrectomy in epiretinal membrane surgery is comparable with 20-gauge vitrectomy and is a safe method with a low complication rate. However, the incidence of postoperative hypotony is more frequent using the 23-gauge system.