Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2009 Nov;80(5):436-44.
doi: 10.1016/j.contraception.2009.03.018. Epub 2009 May 13.

Bleeding pattern and cycle control with an estradiol-based oral contraceptive: a seven-cycle, randomized comparative trial of estradiol valerate/dienogest and ethinyl estradiol/levonorgestrel

Affiliations
Randomized Controlled Trial

Bleeding pattern and cycle control with an estradiol-based oral contraceptive: a seven-cycle, randomized comparative trial of estradiol valerate/dienogest and ethinyl estradiol/levonorgestrel

Hans-Joachim Ahrendt et al. Contraception. 2009 Nov.

Abstract

Background: This study compared the bleeding pattern, cycle control and safety of an oral contraceptive (OC) comprising estradiol valerate/dienogest (E2V/DNG; administered using a dynamic dosing regimen) with a monophasic OC containing ethinyl estradiol 20 mcg/levonorgestrel 100 mcg (EE/LNG). E2V releases estradiol (E2), which is identical to endogenously produced 17beta-estradiol.

Study design: This was a randomized, multicenter, double-blind, double-dummy trial lasting seven cycles in healthy women aged 18-50 years.

Results: Overall, 798 women were randomized and received allocated treatment (399 per group). There were significantly fewer bleeding/spotting days reported by women who received E2V/DNG than those who received EE/LNG [17.3+/-10.4 vs. 21.5+/-8.6, respectively, p<.0001, Reference Period 1 (Days 1-90); and 13.4+/-9.vs. 15.9+/-7.1, respectively, p<.0001, Reference Period 2 (Days 91-180)]. Through Cycles 1-7, the occurrence of scheduled withdrawal bleeding per cycle was 77.7-83.2% with E2V/DNG and 89.5-93.8% with EE/LNG (p<.0001 per cycle). The duration and intensity of scheduled withdrawal bleeding were reduced with E2V/DNG vs. EE/LNG. The incidence of intracyclic bleeding was similar with E2V/DNG (10.5%-18.6%) and EE/LNG (9.9%-17.1%) (p>.05 per cycle). No unintended pregnancies occurred with E2V/DNG, but there was one unintended pregnancy with EE/LNG. Adverse drug reactions occurred in 10.0% and 8.5% of women taking E2V/DNG and EE/LNG, respectively. Overall, 79.4% of women were satisfied with E2V/DNG and 79.9% with EE/LNG.

Conclusions: A novel OC composed of E2V/DNG is associated with an acceptable bleeding profile that is comparable to that of an EE-containing OC.

Trial registration: ClinicalTrials.gov NCT00185367.

PubMed Disclaimer

Publication types

MeSH terms

Associated data