Comparison of the enzyme-linked immunosorbent assay and the indirect hemagglutination test for detection of antibody to cytomegalovirus
- PMID: 198496
- DOI: 10.1093/infdis/136.supplement_2.s337
Comparison of the enzyme-linked immunosorbent assay and the indirect hemagglutination test for detection of antibody to cytomegalovirus
Abstract
Thirty samples of serum were tested for antibody to cytomegalovirus by enzyme-linked immunosorbent assay (ELISA) and indirect hemagglutination (IHA). The two tests were in extremely close agreement. Of the 30 sera evaluated by ELISA, 16 were considered to be positive and 14 were considered negative. In all 16 positive samples, the titers by ELISA were at least twofold to 10-fold higher than the indirect hemagglutination titers. Two of the 14 sera evaluated as negative by the ELISA test had low indirect hemagglutination titers (1:8 and 1:4). They were not detectable at the initial dilution (1:50) of the ELISA test. These two sera might have been classified as positive if the initial dilution in ELISA had been lower than 1:50.
Similar articles
-
Detection of cytomegalovirus antibody with two commercially available assays, an indirect hemagglutination test and an enzyme immunosorbent assay.J Clin Microbiol. 1984 Jul;20(1):9-11. doi: 10.1128/jcm.20.1.9-11.1984. J Clin Microbiol. 1984. PMID: 6086710 Free PMC article.
-
Immunity to human cytomegalovirus measured and compared by complement fixation, indirect fluorescent-antibody, indirect hemagglutination, and enzyme-linked immunosorbent assays.J Clin Microbiol. 1984 Feb;19(2):147-52. doi: 10.1128/jcm.19.2.147-152.1984. J Clin Microbiol. 1984. PMID: 6321544 Free PMC article.
-
Comparison of an enzyme-linked immunoassay with an indirect hemagglutination assay for the detection of antibodies to cytomegalovirus.J Virol Methods. 1984 Oct;9(2):153-61. doi: 10.1016/0166-0934(84)90007-7. J Virol Methods. 1984. PMID: 6096389
-
An evaluation under code of new techniques for the detection of cytomegalovirus antibodies: sensitivity of assays and importance of immune complexes.J Clin Lab Immunol. 1981 Nov;6(3):269-74. J Clin Lab Immunol. 1981. PMID: 6279849
-
Enzyme-linked immunosorbent assay for measurement of antibody against cytomegalovirus and rubella virus in a single serum dilution.J Clin Pathol. 1981 Jun;34(6):665-9. doi: 10.1136/jcp.34.6.665. J Clin Pathol. 1981. PMID: 6265504 Free PMC article.
Cited by
-
A flow cytometry-based method for detecting antibody responses to murine cytomegalovirus infection.J Virol Methods. 2007 Jun;142(1-2):50-8. doi: 10.1016/j.jviromet.2007.01.006. Epub 2007 Feb 15. J Virol Methods. 2007. PMID: 17303259 Free PMC article.
-
Micromodified cytomegalovirus antibody screening test.J Clin Pathol. 1985 Jan;38(1):111-3. doi: 10.1136/jcp.38.1.111. J Clin Pathol. 1985. PMID: 2981903 Free PMC article. No abstract available.
-
Antibody response of patas monkeys to experimental infection with Delta herpesvirus.Eur J Clin Microbiol. 1984 Apr;3(2):158-9. doi: 10.1007/BF02014341. Eur J Clin Microbiol. 1984. PMID: 6723641 No abstract available.
-
Microplate enzyme-linked immunosorbent assay for bovine leukemia virus antibody.J Clin Microbiol. 1981 Jan;13(1):46-8. doi: 10.1128/jcm.13.1.46-48.1981. J Clin Microbiol. 1981. PMID: 6257757 Free PMC article.
-
Immunoglobulin G- and M-specific enzyme-linked immunosorbent assay for detection of dengue antibodies.J Clin Microbiol. 1979 Apr;9(4):498-502. doi: 10.1128/jcm.9.4.498-502.1979. J Clin Microbiol. 1979. PMID: 379040 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources