Comparison of intravenous and intraosseous access by pre-hospital medical emergency personnel with and without CBRN protective equipment
- PMID: 19854554
- DOI: 10.1016/j.resuscitation.2009.09.011
Comparison of intravenous and intraosseous access by pre-hospital medical emergency personnel with and without CBRN protective equipment
Abstract
Introduction: Rapid intravascular access is a prerequisite component of emergency care and resuscitation. Peripheral intravenous (IV) access is the first-choice for most of the medical or trauma patients, but may be delayed in emergency conditions because of various difficulties. Elsewhere, intraosseous (IO) access may now be easily performed with a new semi-automatic battery-powered IO-insertion device (EZ-IO. The aim of this study was to compare the overall time to establish IO infusion with the EZ-IO device and the equivalent time for peripheral IV infusion, performed by emergency personnel in standard (No-CBRN) and in chemical, biological, radiological, and nuclear (CBRN) protective equipment.
Methods: Nine nurses and 16 physicians randomly performed 4 procedures on a training manikin: IV and IO access under No-CBRN conditions and IV and IO under CBRN conditions. The time for each infusion attempt included all the steps essential for a simulated safe clinical use of infusion.
Results: Under No-CBRN conditions, the time to establish IO infusion was shorter than the equivalent IV time (50+/-9 vs 70+/-30s). Similarly, under CBRN conditions, the time for IO infusion was shorter than for IV infusion (65+/-17 vs 104+/-30s). The mean time saved by IO infusion over IV infusion was respectively 20+/-24s (P<0.001) and 39+/-20s (P<0.001) under No-CBRN and CBRN conditions.
Conclusion: The time to establish IO infusion was significantly shorter than that for peripheral IV infusion, under both No-CBRN and CBRN conditions. Further clinical studies are required to confirm that IO access would effectively save time over IV access in real pre-hospital emergency settings.
Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
Similar articles
-
IO versus IV access while wearing personal protective equipment in a HazMat scenario.Prehosp Emerg Care. 2007 Oct-Dec;11(4):467-72. doi: 10.1080/10903120701536982. Prehosp Emerg Care. 2007. PMID: 17907035
-
Evaluation of success rate and access time for an adult sternal intraosseous device deployed in the prehospital setting.Prehosp Disaster Med. 2011 Apr;26(2):127-9. doi: 10.1017/S1049023X11000057. Prehosp Disaster Med. 2011. PMID: 21888733
-
Comparison of two intraosseous infusion systems for adult emergency medical use.Resuscitation. 2008 Sep;78(3):314-9. doi: 10.1016/j.resuscitation.2008.04.004. Epub 2008 Jun 24. Resuscitation. 2008. PMID: 18573590 Clinical Trial.
-
EZ-IO(®) intraosseous device implementation in a pre-hospital emergency service: A prospective study and review of the literature.Resuscitation. 2013 Apr;84(4):440-5. doi: 10.1016/j.resuscitation.2012.11.006. Epub 2012 Nov 14. Resuscitation. 2013. PMID: 23160104 Review.
-
Intraosseous access in the prehospital setting: literature review.Prehosp Disaster Med. 2012 Oct;27(5):468-72. doi: 10.1017/S1049023X12001124. Epub 2012 Aug 9. Prehosp Disaster Med. 2012. PMID: 22877834 Review.
Cited by
-
Resuscitation of the patient with suspected/confirmed COVID-19 when wearing personal protective equipment: A randomized multicenter crossover simulation trial.Cardiol J. 2020;27(5):497-506. doi: 10.5603/CJ.a2020.0068. Epub 2020 May 18. Cardiol J. 2020. PMID: 32419128 Free PMC article. Clinical Trial.
-
Pediatric intravascular access in simulated COVID-19 patients among paramedics wearing personal protective equipment.Resusc Plus. 2021 Mar;5:100073. doi: 10.1016/j.resplu.2020.100073. Epub 2020 Dec 29. Resusc Plus. 2021. PMID: 33521707 Free PMC article. No abstract available.
-
Efficacy of the EZ-IO needle driver for out-of-hospital intraosseous access--a preliminary, observational, multicenter study.Scand J Trauma Resusc Emerg Med. 2011 Oct 26;19:65. doi: 10.1186/1757-7241-19-65. Scand J Trauma Resusc Emerg Med. 2011. PMID: 22029625 Free PMC article.
-
G-CSF Administration after the Intraosseous Infusion of Hypertonic Hydroxyethyl Starches Accelerating Wound Healing Combined with Hemorrhagic Shock.Biomed Res Int. 2016;2016:5317630. doi: 10.1155/2016/5317630. Epub 2016 Feb 17. Biomed Res Int. 2016. PMID: 26989687 Free PMC article.
-
Comparison of routes for achieving parenteral access with a focus on the management of patients with Ebola virus disease.Cochrane Database Syst Rev. 2015 Feb 26;2015(2):CD011386. doi: 10.1002/14651858.CD011386.pub2. Cochrane Database Syst Rev. 2015. PMID: 25914907 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical