Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Nov;30(5):973-80.
doi: 10.1002/jmri.21935.

Utility of phase contrast MR imaging for assessment of pulmonary flow and pressure estimation in patients with pulmonary hypertension: comparison with right heart catheterization and echocardiography

Affiliations
Comparative Study

Utility of phase contrast MR imaging for assessment of pulmonary flow and pressure estimation in patients with pulmonary hypertension: comparison with right heart catheterization and echocardiography

Munenobu Nogami et al. J Magn Reson Imaging. 2009 Nov.

Abstract

Purpose: To compare the utility of phase contrast MR imaging (PC-MRI) for assessment of pulmonary flow and pressure estimation with that of right heart catheterization and echocardiography (cardiac US) in patients with pulmonary arterial hypertension (PAH).

Materials and methods: Twenty consecutive patients with suspected PAH underwent PC-MRI, cardiac US, and right heart catheterization. In each patient, PC-MRI was acquired by cine 2D-PC method on a 1.5 Tesla scanner, and stroke volume (SV) and pulmonary arterial systolic pressure (PASP) were assessed by using the modified Bernoulli's equation. To evaluate the agreements of SV and PASP among the three methods, correlations and limits of agreement among the three methods were statistically assessed by using the Bland-Altman's analyses.

Results: The correlations and limits of agreement for SV and PASP between PC-MRI and catheterization (r = 0.96, r(2) = 0.94, 1.1 +/- 6.9 mL and r = 0.94, r(2) = 0.88, -3.2 +/- 14.5 mmHg, respectively) were better than between cardiac US and catheterization (r = 0.01, r(2) < 0.01, 8.9 +/- 42.1 mL and r = 0.86, r(2) = 0.72, -5.9 +/- 27.7 mmHg, respectively).

Conclusion: PC-MRI is more compatible with right heart catheterization than cardiac US in pulmonary flow and pressure estimation.

PubMed Disclaimer

Publication types

LinkOut - more resources