False-positive urine pregnancy test in a woman with adenomysosis
- PMID: 19857433
- DOI: 10.1016/j.ajem.2008.12.023
False-positive urine pregnancy test in a woman with adenomysosis
Abstract
We present a case of a 39-year-old woman presenting to the emergency department with persistent vaginal bleeding with myoma and endometrium thickness. The qualitative urine human chorionic gonadotropin (hCG) showed positive result, however, the quantitative serum hCG had negative result. The negative serum hCG result suggests that the false-positive result was not caused by elevated circulating hCG. According to the urine hCG one-step pregnancy device, 1 mg/dL of hemoglobin may not interference the pregnancy result. Nevertheless, we found that the hemoglobin level was 40 mg/dL in the urine specimen. We designed a in vitro experiment to evaluate the effects of hemoglobin on urine pregnancy test. The concentrations of hemoglobin from 5 to 500 mg/dL did not yield a positive urine pregnancy test. On the basis of our findings, the false positive pregnancy test was not caused by hemoglobin. It is important to confirm a suspected false-positive urine hCG test using a quantitative serum hCG test. Although it is not certain the mechanism for false positive reaction in this peculiar sample, the ACON urine hCG one-step pregnancy will occasionally yield a false-positive result in this class of patients.
Similar articles
-
The need for a quantitative urine hCG assay.Clin Biochem. 2009 May;42(7-8):676-83. doi: 10.1016/j.clinbiochem.2008.10.018. Epub 2008 Nov 6. Clin Biochem. 2009. PMID: 19026624
-
One-year experience with day-of-surgery pregnancy testing before elective orthopedic procedures.Anesth Analg. 2008 Apr;106(4):1127-31, table of contents. doi: 10.1213/ane.0b013e31816788df. Anesth Analg. 2008. PMID: 18349183
-
Evaluation of the beta-Neocept test for early pregnancy.Can Med Assoc J. 1984 Sep 15;131(6):583-5. Can Med Assoc J. 1984. PMID: 6206935 Free PMC article.
-
Update on pregnancy testing.Prim Care. 1986 Dec;13(4):667-77. Prim Care. 1986. PMID: 3541014 Review.
-
Pregnancy tests: evaluation of current status.Crit Rev Clin Lab Sci. 1984;19(4):353-9. doi: 10.3109/10408368409165767. Crit Rev Clin Lab Sci. 1984. PMID: 6373143 Review.
Cited by
-
A Case of a False-Positive Urine Pregnancy Test and Delayed Diagnosis of Obstructive Pyelonephritis.Am J Case Rep. 2020 Mar 25;21:e920440. doi: 10.12659/AJCR.920440. Am J Case Rep. 2020. PMID: 32210220 Free PMC article.
-
Pregnancy Reasonably Excluded Guide (PREG) Evaluation of Pregnancy Status Before Contraceptive Procedures: Improved Availability of Same-Day Insertion.Mayo Clin Proc Innov Qual Outcomes. 2020 Jun 5;4(3):295-304. doi: 10.1016/j.mayocpiqo.2020.01.008. eCollection 2020 Jun. Mayo Clin Proc Innov Qual Outcomes. 2020. PMID: 32542221 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical