Strategies for online organ motion correction for intensity-modulated radiotherapy of prostate cancer: prostate, rectum, and bladder dose effects
- PMID: 19857789
- DOI: 10.1016/j.ijrobp.2009.04.034
Strategies for online organ motion correction for intensity-modulated radiotherapy of prostate cancer: prostate, rectum, and bladder dose effects
Abstract
Purpose: To quantify and evaluate the accumulated prostate, rectum, and bladder dose for several strategies including rotational organ motion correction for intensity-modulated radiotherapy (IMRT) of prostate cancer using realistic organ motion data.
Methods and materials: Repeat computed tomography (CT) scans of 19 prostate patients were used. Per patient, two IMRT plans with different uniform margins were created. To quantify prostate and seminal vesicle motion, repeat CT clinical target volumes (CTVs) were matched onto the planning CTV using deformable registration. Four different strategies, from online setup to full motion correction, were simulated. Rotations were corrected for using gantry and collimator angle adjustments. Prostate, rectum, and bladder doses were accumulated for each patient, plan, and strategy. Minimum CTV dose (D(min)), rectum equivalent uniform dose (EUD, n = 0.13), and bladder surface receiving >or=78 Gy (S78), were calculated.
Results: With online CTV translation correction, a 7-mm margin was sufficient (i.e., D(min) >or= 95% of the prescribed dose for all patients). A 4-mm margin required additional rotational correction. Margin reduction lowered the rectum EUD(n = 0.13) by approximately 2.6 Gy, and the bladder S78 by approximately 1.9%.
Conclusions: With online correction of both translations and rotations, a 4-mm margin was sufficient for 15 of 19 patients, whereas the remaining four patients had an underdosed CTV volume <1%. Margin reduction combined with online corrections resulted in a similar or lower dose to the rectum and bladder. The more advanced the correction strategy, the better the planned and accumulated dose agreed.
Similar articles
-
Strategy for online correction of rotational organ motion for intensity-modulated radiotherapy of prostate cancer.Int J Radiat Oncol Biol Phys. 2007 Dec 1;69(5):1608-17. doi: 10.1016/j.ijrobp.2007.08.042. Epub 2007 Oct 4. Int J Radiat Oncol Biol Phys. 2007. PMID: 17919845
-
Evaluation of online/offline image guidance/adaptation approaches for prostate cancer radiation therapy.Int J Radiat Oncol Biol Phys. 2015 Apr 1;91(5):1026-33. doi: 10.1016/j.ijrobp.2014.12.043. Int J Radiat Oncol Biol Phys. 2015. PMID: 25832693
-
Dosimetric and radiobiological consequences of computed tomography-guided adaptive strategies for intensity modulated radiation therapy of the prostate.Int J Radiat Oncol Biol Phys. 2013 Dec 1;87(5):874-80. doi: 10.1016/j.ijrobp.2013.07.006. Epub 2013 Aug 24. Int J Radiat Oncol Biol Phys. 2013. PMID: 23978708
-
Current status of intensity-modulated radiation therapy for prostate cancer: History, clinical results and future directions.Int J Urol. 2019 Aug;26(8):775-784. doi: 10.1111/iju.14011. Epub 2019 May 21. Int J Urol. 2019. PMID: 31115116 Review.
-
Adaptive optimization by 6 DOF robotic couch in prostate volumetric IMRT treatment: rototranslational shift and dosimetric consequences.J Appl Clin Med Phys. 2015 Sep 8;16(5):35-45. doi: 10.1120/jacmp.v16i5.5525. J Appl Clin Med Phys. 2015. PMID: 26699314 Free PMC article. Review.
Cited by
-
Roll and pitch set-up errors during volumetric modulated arc delivery: can adapting gantry and collimator angles compensate?Strahlenther Onkol. 2015 Mar;191(3):272-80. doi: 10.1007/s00066-014-0766-2. Epub 2014 Nov 28. Strahlenther Onkol. 2015. PMID: 25430597
-
Comparison of MRI visualization between linearly placed iron-containing and non-iron-containing fiducial markers for prostate radiotherapy.Br J Radiol. 2018 Feb;91(1082):20170612. doi: 10.1259/bjr.20170612. Epub 2017 Nov 28. Br J Radiol. 2018. PMID: 29120662 Free PMC article.
-
Dynamic intrafractional position monitoring with implanted fiducial markers for enhanced accuracy in radiotherapy of prostate cancer.Phys Eng Sci Med. 2023 Dec;46(4):1365-1374. doi: 10.1007/s13246-023-01304-w. Epub 2023 Jul 31. Phys Eng Sci Med. 2023. PMID: 37523057 Free PMC article.
-
Target margins in radiotherapy of prostate cancer.Br J Radiol. 2016 Nov;89(1067):20160312. doi: 10.1259/bjr.20160312. Epub 2016 Jul 20. Br J Radiol. 2016. PMID: 27377353 Free PMC article. Review.
-
eNAL++: a new and effective off-line correction protocol for rotational setup errors when using a robotic couch.J Appl Clin Med Phys. 2015 Nov 8;16(6):177-185. doi: 10.1120/jacmp.v16i6.5583. J Appl Clin Med Phys. 2015. PMID: 26699569 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical