Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model
- PMID: 19875312
- DOI: 10.1016/j.tripleo.2009.07.041
Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model
Abstract
Objectives: The aim of this study was to compare the diagnostic accuracy of an intraoral photostimulable storage phosphor (PSP) plate system and cone-beam computerized tomography scanning (CBCT) for detection of experimentally induced transverse root fractures and to evaluate differences between original images and images enhanced with high-pass filters.
Study design: Sixty-nine extracted human teeth, 34 with root fractures and 35 without, were examined under standardized conditions using an intraoral PSP system (Digora Optime; Soredex). The images were saved in original 8-bit format and in a version sharpened with a high-pass filter. The teeth were examined with CBCT (i-Cat; Imaging Sciences) in 2 resolutions: 0.125 mm and 0.25 mm voxel size. Original images were saved together with images enhanced with 2 high-pass filters, sharpen and angio-sharpen. Six observers scored the presence of a root fracture in all modalities in random order. Sensitivity, specificity, and accuracy [(true positives + true negatives)/all scores] were calculated for each modality and each observer. Differences were estimated by analyzing the binary data, assuming additive effects of observer and modality in a generalized linear model.
Results: High-resolution original CBCT images had higher sensitivity (P < .05) than lower-resolution images and PSP images (0.125 mm resolution 87%, 0.25 mm resolution 72%, and PSP 74%). Angio-sharpen-filtered images for both CBCT resolutions had higher sensitivities (P < .02) than the original images (0.125 mm resolution: 95% vs. 87%; 0.25 mm resolution: 81% vs. 72%). There was no significant difference between the lower-resolution CBCT and PSP images. Only small differences in specificity were seen between modalities, and accuracy was higher for high-resolution CBCT than for the other modalities (P < .03).
Conclusions: High-resolution i-Cat CBCT images resulted in an increase in sensitivity without jeopardizing specificity for detection of transverse root fractures compared with lower-resolution CBCT images, which were not more accurate than periapical PSP images. The angio-sharpen high-pass filter improved sensitivity in the high-resolution CBCT images in this in vitro model.
Similar articles
-
Influence of cone beam CT enhancement filters on diagnosis ability of longitudinal root fractures.Dentomaxillofac Radiol. 2014;43(3):20130374. doi: 10.1259/dmfr.20130374. Epub 2014 Jan 22. Dentomaxillofac Radiol. 2014. PMID: 24408819 Free PMC article.
-
Effectiveness of limited cone-beam computed tomography in the detection of horizontal root fracture.Dent Traumatol. 2009 Jun;25(3):256-61. doi: 10.1111/j.1600-9657.2009.00770.x. Dent Traumatol. 2009. PMID: 19583573
-
Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth.Dentomaxillofac Radiol. 2013;42(7):20120404. doi: 10.1259/dmfr.20120404. Epub 2013 Apr 26. Dentomaxillofac Radiol. 2013. PMID: 23625067 Free PMC article. Clinical Trial.
-
Is cone-beam computed tomography more accurate than periapical radiography for detection of vertical root fractures? A systematic review and meta-analysis.BMC Med Imaging. 2024 Oct 22;24(1):286. doi: 10.1186/s12880-024-01472-5. BMC Med Imaging. 2024. PMID: 39438817 Free PMC article.
-
Contemporary management of horizontal root fractures to the permanent dentition: diagnosis--radiologic assessment to include cone-beam computed tomography.Pediatr Dent. 2013 Mar-Apr;35(2):120-4. Pediatr Dent. 2013. PMID: 23635979 Review.
Cited by
-
Effect of Amperage and Field of View on Detection of Vertical Root Fracture in Teeth with Intracanal Posts.Iran Endod J. 2016 Summer;11(3):202-7. doi: 10.7508/iej.2016.03.011. Epub 2016 May 1. Iran Endod J. 2016. PMID: 27471532 Free PMC article.
-
A novel insertion design of fiber materials for the adhesive reattachment in vertically fractured teeth.PLoS One. 2021 Oct 13;16(10):e0258534. doi: 10.1371/journal.pone.0258534. eCollection 2021. PLoS One. 2021. PMID: 34644356 Free PMC article.
-
Effect of Filtration and Slice Thickness of Cone-Beam Computed Tomography Images on Occlusal Caries Detection: An Ex Vivo Study.J Dent (Tehran). 2018 Sep;15(5):283-293. J Dent (Tehran). 2018. PMID: 30833974 Free PMC article.
-
Detection accuracy of condylar defects in cone beam CT images scanned with different resolutions and units.Dentomaxillofac Radiol. 2014;43(3):20130414. doi: 10.1259/dmfr.20130414. Epub 2014 Jan 22. Dentomaxillofac Radiol. 2014. PMID: 24408818 Free PMC article.
-
Influence of CBCT enhancement filters on diagnosis of vertical root fractures: a simulation study in endodontically treated teeth with and without intracanal posts.Dentomaxillofac Radiol. 2015;44(5):20140352. doi: 10.1259/dmfr.20140352. Dentomaxillofac Radiol. 2015. PMID: 25666446 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous