Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Jul-Sep;20(3):277-81.
doi: 10.4103/0970-9290.57357.

Flexural modulus, flexural strength, and stiffness of fiber-reinforced posts

Affiliations
Free article
Comparative Study

Flexural modulus, flexural strength, and stiffness of fiber-reinforced posts

Veridiana R Novais et al. Indian J Dent Res. 2009 Jul-Sep.
Free article

Abstract

Background: The radiopacity degree of posts is not enough for adequate visualization during radiographic analyses. Glass fiber post with stainless steel reinforcement has been fabricated in an attempt to overcome this limitation.

Aim: This study was designed to determine the influence of this metal reinforcement on the post mechanical properties.

Materials and methods: This study evaluated flexural modulus (E), flexural strength (sigma), and stiffness (S) of five different fiber post systems (n = 5): RfX (Reforpost Glass Fiber RX; Angelus, Londrina, PR, Brazil); RG (Reforpost Glass Fiber, Angelus); RC (Reforpost Carbon Fiber, Angelus); FP (Fibrekor Post; Jeneric Pentron Inc., Wallingford, CT, USA); and CP (C-Post; Bisco Dental Products, Schaumburg, IL, USA), testing the hypothesis that the insertion of a metal reinforcement (RfX) jeopardizes the mechanical properties of a glass fiber post. Posts were loaded in three-point bending using a testing machine with a crosshead speed of 0.5 mm/min.

Results: The results were statistically analyzed using one-way ANOVA and Tukey's multiple range tests (a = 0.05). Mean and standard deviation values of E (GPa), s (MPa), and S (N/mm) were as follows: RfX: 10.8 +/- 1.6, 598.0 +/- 52.0, 132.0 +/- 21.9; RG: 10.6 +/- 1.0, 562.0 +/- 24.9, 137.8 +/- 5.5; RC: 15.9 +/- 2.4, 680.5 +/- 34.8, 190.9 +/- 12.9; FP: 10.9 +/- 1.4, 586.8 +/- 21.9, 122.4 +/- 17.3; CP: 6.3 +/- 1.7, 678.1 +/- 54.2, 246.0 +/- 41.7. Carbon fiber posts showed the highest mean s values (P < 0.05). In addition, RC showed the highest mean E value and CP showed the highest mean S value (P < 0.05).

Conclusion: The hypothesis was rejected since the metal reinforcement in the glass fiber post (RfX) does not decrease the mechanical property values. Posts reinforced with carbon fibers have a higher flexural strength than glass fiber posts, although all posts showed similar mechanical property values with dentin.

PubMed Disclaimer

Publication types