Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2010 Mar;33(3):353-67.
doi: 10.1111/j.1540-8159.2009.02590.x. Epub 2009 Nov 2.

Bridging a temporary high risk of sudden arrhythmic death. Experience with the wearable cardioverter defibrillator (WCD)

Affiliations
Review

Bridging a temporary high risk of sudden arrhythmic death. Experience with the wearable cardioverter defibrillator (WCD)

Helmut U Klein et al. Pacing Clin Electrophysiol. 2010 Mar.

Abstract

The implantable cardioverter defibrillator (ICD) is able to reduce sudden arrhythmic death in patients who are considered to be at high risk. However, the arrhythmic risk may be increased only temporarily as long as the proarrhythmic conditions persist, left ventricular ejection fraction remains low, or heart failure prevails. The wearable cardioverter defibrillator (WCD) represents an alternative approach to prevent sudden arrhythmic death until either ICD implantation is clearly indicated or the arrhythmic risk is considered significantly lower or even absent. The WCD is also indicated for interrupted protection by an already implanted ICD, temporary inability to implant an ICD, and lastly refusal of an indicated ICD by the patient. The WCD is not an alternative to the ICD, but a device that may contribute to better selection of patients for ICD therapy. The WCD has the characteristics of an ICD, but does not need to be implanted, and it has similarities with an external defibrillator, but does not require a bystander to apply lifesaving shocks when necessary. The WCD was introduced into clinical practice about 8 years ago, and indications for its use are currently expanding. This article describes the technological aspects of the WCD, discusses current indications for its use, and reviews the clinical studies with the WCD. Additionally, data are reported on the clinical experience with the WCD based on 354 patients from Germany hospitalized between 2000 and 2008 who wore the WCD for a mean of 3 months.

PubMed Disclaimer

Publication types

LinkOut - more resources