The cardiovascular response to an acute 1800-microT, 60-Hz magnetic field exposure in humans
- PMID: 19902234
- DOI: 10.1007/s00420-009-0484-8
The cardiovascular response to an acute 1800-microT, 60-Hz magnetic field exposure in humans
Abstract
Purpose: Previously published literature has suggested an effect of extremely low-frequency (ELF) magnetic fields (MF) on human heart rate (HR) and heart rate variability (HRV). The combined response of the microcirculation and macrocirculation to ELF MF exposure has not previously been studied in humans. This study investigated the effects of 1-h exposure to an 1800-muT, 60-Hz MF on human microcirculation (represented in this study as skin blood perfusion), HR, low-frequency HRV, and high-frequency HRV.
Methods: Fifty-eight volunteers were recruited to partake in a double-blinded, counterbalanced study consisting of two testing sessions (real and sham) administered on separate days. Each session included four consecutive blocks of measurements, separated by 15-min rest periods, allowing measurement of cumulative and residual MF effects. Within subjects, ANOVA were conducted on each of the measured parameters.
Results: A decrease of skin blood perfusion and HR, and an increase of HRV were observed over blocks (p < 0.05). No session by block interactions were found for any of the cardiovascular parameters which would have suggested a MF effect (p > 0.05). A session by block interaction (p < 0.001) and a MF order effect (sham or real exposure first, p < 0.05) were observed for skin surface temperature.
Conclusions: The MF used in this experiment did not affect cardiovascular parameters. Although an alternative explanation for why skin surface temperatures decreased in the sham and not in the real exposure condition is presented, the possibility of a MF effect cannot be excluded.
Similar articles
-
The response of the human circulatory system to an acute 200-μT, 60-Hz magnetic field exposure.Int Arch Occup Environ Health. 2011 Mar;84(3):267-77. doi: 10.1007/s00420-010-0543-1. Epub 2010 May 25. Int Arch Occup Environ Health. 2011. PMID: 20496180
-
Absence of daytime 50 Hz, 100 microT(rms) magnetic field or bright light exposure effect on human performance and psychophysiological parameters.Bioelectromagnetics. 2005 Apr;26(3):225-33. doi: 10.1002/bem.20070. Bioelectromagnetics. 2005. PMID: 15768425 Clinical Trial.
-
Can extremely low frequency alternating magnetic fields modulate heart rate or its variability in humans?Auton Neurosci. 2003 Apr 30;105(1):53-61. doi: 10.1016/S1566-0702(02)00296-5. Auton Neurosci. 2003. PMID: 12742191
-
Human electrophysiological and cognitive effects of exposure to ELF magnetic and ELF modulated RF and microwave fields: a review of recent studies.Bioelectromagnetics. 2002 Feb;23(2):144-57. doi: 10.1002/bem.107. Bioelectromagnetics. 2002. PMID: 11835261 Review.
-
A literature review: the cardiovascular effects of exposure to extremely low frequency electromagnetic fields.Int Arch Occup Environ Health. 2009 Aug;82(8):919-33. doi: 10.1007/s00420-009-0404-y. Epub 2009 Feb 17. Int Arch Occup Environ Health. 2009. PMID: 19221783 Review.
Cited by
-
A 50 Hz magnetic field affects hemodynamics, ECG and vascular endothelial function in healthy adults: A pilot randomized controlled trial.PLoS One. 2021 Aug 5;16(8):e0255242. doi: 10.1371/journal.pone.0255242. eCollection 2021. PLoS One. 2021. PMID: 34351946 Free PMC article. Clinical Trial.
-
Neurophysiological and behavioral effects of a 60 Hz, 1,800 μT magnetic field in humans.Eur J Appl Physiol. 2012 May;112(5):1751-62. doi: 10.1007/s00421-011-2130-x. Epub 2011 Sep 6. Eur J Appl Physiol. 2012. PMID: 21894451
-
The response of the human circulatory system to an acute 200-μT, 60-Hz magnetic field exposure.Int Arch Occup Environ Health. 2011 Mar;84(3):267-77. doi: 10.1007/s00420-010-0543-1. Epub 2010 May 25. Int Arch Occup Environ Health. 2011. PMID: 20496180
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical