Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Jan;27(1):175-86.
doi: 10.1007/s11095-009-9994-z. Epub 2009 Nov 10.

The interaction between the oropharyngeal geometry and aerosols via pressurised metered dose inhalers

Affiliations
Comparative Study

The interaction between the oropharyngeal geometry and aerosols via pressurised metered dose inhalers

T Ehtezazi et al. Pharm Res. 2010 Jan.

Abstract

Purpose: This study investigated the effect of oropharyngeal geometry on inhaled aerosol characteristics via pressurised metered dose inhalers (pMDIs), both with or without spacers.

Methods: Seven adult oropharyngeal models with different centreline lengths, total volumes, and degrees of constriction were employed as induction ports for a laser diffraction particle size analyser and cascade impactor. Particle size change over time, mass median aerodynamic diameter (MMAD), average median volume diameter (D(V)50), inhaled doses, and oropharyngeal depositions (percentage of the nominal dose) for aerosols via suspension and ultrafine pMDIs with or without spacers at 30 l/min airflow were determined.

Results: Variations in oropharyngeal geometry caused significant variations in inhaled particle size distributions, doses, oropharyngeal drug depositions, and particle size change over time when pMDIs were used without spacers. However, inhaled aerosol characteristics had marginal variations for the ultrafine pMDI plus large volume spacer (MMAD range: 0.69-0.78 microm, D(V)50 range: 1.27-1.36 microm, inhaled dose range: 46.46-52.92%). It was found that the amounts of inhaled aerosol particles with aerodynamic size of less than 0.83 microm via pMDIs plus large volume spacer were slightly affected by the oropharyngeal geometry.

Conclusion: Inhaling ultrafine aerosols via spacers may reduce the effect of oropharyngeal geometry on inhaled aerosol properties.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Arch Dis Child. 1998 Jul;79(1):12-7 - PubMed
    1. J Asthma. 2008 Sep;45(7):561-7 - PubMed
    1. Eur Respir J. 2007 Feb;29(2):299-306 - PubMed
    1. Chest. 2003 Jun;123(6):2083-8 - PubMed
    1. J Allergy Clin Immunol. 2002 Mar;109(3):410-8 - PubMed

Publication types

LinkOut - more resources