[Treatment of fracture of multiple ribs with absorbable rib fixed nail and dacron flap in 12 patients]
- PMID: 19902768
[Treatment of fracture of multiple ribs with absorbable rib fixed nail and dacron flap in 12 patients]
Abstract
Objective: To introduce the methods of dacron flap application and its indications in treating fracture of multiple ribs, in order to reduce the incidence of the complications of fracture displacement.
Methods: From September 2006 to March 2008, 12 patients with fracture of multiple ribs were treated with absorbable rib fixed nail and dacron flap. Included 8 males and 4 females,the age was from 22 to 51 years with an average of 38.2 years,the operative time was 2 hours to 3 days after injured. All the patients were closed injury and simultaneously accompanied with significant chest pain and chest tightness. 4 cases with dyspnea, blood in sputum and blood oxygen saturation decreased. The X-ray showed 3 cases of unilateral fracture and 9 cases of bilateral rib fractures and all cases accompanied with hemopneumothorax.
Results: All patients were followed up from 2 to 26 months with an average of 8 months. All the fractures healed. According to clinical criteria, pain, breathing, ribs alignment etc. to observe the effect, 10 cases got excellent result, 1 case good, 1 case poor.
Conclusion: It is safe and effective to use absorbable rib fixed nails and dacron flap for treating fracture of multiple ribs and especially for the patients of osteoporosis, comminuted fracture or oblique fracture.
Similar articles
-
[Internal fixation treatment of multiple rib fractures with absorbable rib-connecting-pins].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2011 Jan;25(1):100-3. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2011. PMID: 21351621 Chinese.
-
[Effect of interlocking intramedullary nail in treatment of open tibial and fibula fractures].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2009 Mar;23(3):268-70. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2009. PMID: 19366130 Chinese.
-
[Application of auto-control micro-motion intramedullary locking nail in the treatment of femoral shaft fractures].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2008 Jun;22(6):696-9. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2008. PMID: 18630566 Chinese.
-
Rib fracture fixation: controversies and technical challenges.Am Surg. 2010 Aug;76(8):793-802. Am Surg. 2010. PMID: 20726406 Review.
-
Surgical management of multiple painful rib nonunions in patient with a history of severe shoulder girdle trauma: a case report and literature review.J Orthop Trauma. 2009 Sep;23(8):600-4. doi: 10.1097/BOT.0b013e3181a15e90. J Orthop Trauma. 2009. PMID: 19704277 Review.