Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand
- PMID: 19904533
- PMCID: PMC3014491
- DOI: 10.1007/s00264-009-0903-1
Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand
Abstract
Leg length discrepancy following total hip replacement (THR) can contribute to poor hip function. Abnormal gait, pain, neurological disturbance and patient dissatisfaction have all been described as a result of leg length inequality after THR. The purpose of this study was to determine whether the use of computer navigation in THR can improve limb length restoration and early clinical outcomes. We performed a matched-pair study comparing 48 computer-assisted THR with 48 THRs performed using a traditional freehand alignment method. The same implant with a straight non-modular femoral stem was used in all cases. The navigation system used allowed the surgeon to monitor both acetabular cup placement and all the phases of femoral stem implantation including rasping. Patients were matched for age, sex, arthritis level, pre-operative diagnosis and pre-operative leg length discrepancy. At a minimum follow-up of six months, limb length discrepancy was measured using digital radiographs and a standardised protocol. The number of patients with a residual discrepancy of 10 mm or more and/or a post-operative over-lengthening were measured. The clinical outcome was evaluated using both the Harris Hip Score and the normalised Western Ontario and McMaster Universities (WOMAC) Arthritis Index. Restoration of limb length was significantly better in the computer-assisted THR group. The number of patients with a residual limb length discrepancy greater than 10 mm and/or a post-operative over-lengthening was significantly lower. No significant difference in the Harris Hip Score or normalised WOMAC Arthritis Index was seen between the two groups. The surgical time was significantly longer in the computer-assisted THR group. No post-operative dislocations were seen.
Figures
Similar articles
-
Comparison of limb-length discrepancy after THA: with and without computer navigation.Orthopedics. 2013 May;36(5):e543-7. doi: 10.3928/01477447-20130426-13. Orthopedics. 2013. PMID: 23672903
-
Leg length discrepancy and lower limb alignment after total hip arthroplasty in unilateral hip osteoarthritis patients.J Orthop Sci. 2013 Nov;18(6):969-76. doi: 10.1007/s00776-013-0457-3. Epub 2013 Aug 21. J Orthop Sci. 2013. PMID: 23963590
-
Leg length discrepancy, dislocation rate, and offset in total hip replacement using a short modular stem: navigation vs conventional freehand.Orthopedics. 2008 Oct;31(10 Suppl 1):orthosupersite.com/view.asp?rID=35541. Orthopedics. 2008. PMID: 19298037 Clinical Trial.
-
Imageless navigation for primary total hip arthroplasty: a meta-analysis study.J Orthop Traumatol. 2022 Apr 15;23(1):21. doi: 10.1186/s10195-022-00636-9. J Orthop Traumatol. 2022. PMID: 35426527 Free PMC article.
-
Lower limb length and offset in total hip arthroplasty.Orthop Traumatol Surg Res. 2016 Feb;102(1 Suppl):S9-20. doi: 10.1016/j.otsr.2015.11.001. Epub 2016 Jan 18. Orthop Traumatol Surg Res. 2016. PMID: 26797005 Review.
Cited by
-
Hip Offset and Leg Length Equalization in Direct Anterior Approach Total Hip Arthroplasty without Preoperative Templating.Hawaii J Health Soc Welf. 2019 Nov;78(11 Suppl 2):26-28. Hawaii J Health Soc Welf. 2019. PMID: 31773108 Free PMC article.
-
Defining the Learning Period of a Novel Imageless Navigation System for Posterior Approach Total Hip Arthroplasty: Analysis of Surgical Time and Accuracy.Indian J Orthop. 2023 Dec 9;58(2):121-126. doi: 10.1007/s43465-023-01060-9. eCollection 2024 Feb. Indian J Orthop. 2023. PMID: 38312909 Free PMC article.
-
Comparing cup placement, leg length, and offset discrepancy after total hip arthroplasty between CT-based robotic arm-assisted and navigation systems.Bone Jt Open. 2025 Jan 1;6(1):3-11. doi: 10.1302/2633-1462.61.BJO-2024-0173.R1. Bone Jt Open. 2025. PMID: 39740687 Free PMC article.
-
Does the utilization of fluoroscopy affect the accuracy of prosthesis position in patients undergoing hip replacement surgery via the direct anterior approach compared to the posterolateral approach for an experienced surgeon? A single-center retrospective study.BMC Musculoskelet Disord. 2024 Oct 15;25(1):816. doi: 10.1186/s12891-024-07917-w. BMC Musculoskelet Disord. 2024. PMID: 39407225 Free PMC article.
-
A comparison of two different navigated hip replacement techniques on leg length discrepancy.J Orthop. 2018 Feb 21;15(3):765-767. doi: 10.1016/j.jor.2018.02.005. eCollection 2018 Sep. J Orthop. 2018. PMID: 29946201 Free PMC article.
References
-
- Barrak RL. Dislocation after total hip arthroplasty: implant design and orientation. J Am Acad Orthop Surg. 2003;11:89–99. - PubMed
-
- Bellamy N. WOMAC: a 20-year experiential review of a patient-centered self-reported health status questionnaire. J Rheumatol. 2002;29:2473–2476. - PubMed
-
- Braun A, Lazovic D, Zigan R. Modular short-stem prosthesis in total hip arthroplasty: implant positioning and the influence of navigation. Orthopedics. 2007;30(10 Suppl):S148–S152. - PubMed
-
- Clark CR, Huddleston HD, Schoch EP, 3rd, Thomas BJ. Leg-length discrepancy after total hip arthroplasty. J Am Acad Orthop Surg. 2006;14(1):38–45. - PubMed
-
- Confalonieri N, Manzotti A, Montironi F, Pullen C (2008) Leg length discrepancy, dislocation rate, and offset in total hip replacement using a short modular stem: navigation vs conventional freehand. Orthopedics 31(10 Suppl 1):pii:orthosupersite.com/view.asp?rID=35541 - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical