Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Mar;26(3):215-22.
doi: 10.1016/j.dental.2009.10.003. Epub 2009 Nov 11.

Does a low-shrinking composite induce less stress at the adhesive interface?

Affiliations
Free article
Comparative Study

Does a low-shrinking composite induce less stress at the adhesive interface?

Annelies Van Ende et al. Dent Mater. 2010 Mar.
Free article

Abstract

Objectives: Polymerization shrinkage of a composite in a high configuration-factor (C-factor) cavity leads to polymerization shrinkage stress. In the prevention of high polymerization shrinkage stress, a low-shrinking silorane composite (Filtek Silorane, FS, 3M ESPE) was recently marketed. Therefore, we investigated the effect of C-factor (flat surface vs. class-I cavity) and different composite application protocols on the bonding effectiveness of a low-shrinking composite to human dentin.

Methods: A low-shrinking silorane-based composite (FS) and a conventional methacrylate-based composite (Filtek Z100, 3M-ESPE) were bonded to standardized occlusal class-I cavities (4 mm x 4 mm x 2.5 mm) and to flat mid-coronal dentin surfaces using the two-step self-etch adhesive 'Silorane System Adhesive' (3M-ESPE). Eight experimental groups were formed, according to the following treatment protocols: Z100 'flat'(1), Z100 'cavity'(2), FS 'flat'(3), FS 'flat/bulk-filled'(4), FS 'cavity/bulk-filled'(5), FS 'cavity/layered-filled'(6), FS 'cavity/flowable cured'(7) and FS 'cavity/flowable uncured'(8). For each group, at least 5 teeth were used. After 1 week of water storage, the teeth were sectioned to 1 mm x 1 mm (non-trimmed) sticks to measure the micro-tensile bond strength (microTBS).

Results: No statistical difference in microTBS was recorded between Z100 'flat'(1) and FS 'flat'(3). Bonding to class-I cavity dentin lowered the microTBS in all groups, but this was only statistically significant for FS 'cavity/bulk-filled'(5) and FS 'cavity/flowable uncured'(8).

Significance: Using the two-step self-etch Silorane System Adhesive, the conventional composite Filtek Z100 and the low-shrinking composite Filtek Silorane bonded equally well to dentin. Bulk-filling with Filtek Silorane (FS 'flat/bulk-filled'(4)) significantly decreased the microTBS, suggesting that factors other than polymerization shrinkage influenced the microTBS.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources