A visual context-awareness-based sleeping-respiration measurement system
Abstract
Due to the rapid growth of the elderly population, improving specific aspects of elderly healthcare has become more important. Sleeping care systems for the elderly are rare. In this paper, we propose a visual context-aware-based sleeping-respiration measurement system that measures the respiration information of elderly sleepers. Accurate respiration measurement requires considering all possible contexts for the sleeping person. The proposed system consists of a body-motion-context-detection subsystem, a respiration-context-detection subsystem, and a fast motion-vector-estimation-based respiration measurement subsystem. The system yielded accurate respiratory measurements for our study population.
Similar articles
-
An impulse radio ultrawideband system for contactless noninvasive respiratory monitoring.IEEE Trans Biomed Eng. 2013 Jun;60(6):1509-17. doi: 10.1109/TBME.2012.2237401. Epub 2013 Jan 9. IEEE Trans Biomed Eng. 2013. PMID: 23314764
-
Intensity-modulated microbend fiber optic sensor for respiratory monitoring and gating during MRI.IEEE Trans Biomed Eng. 2013 Sep;60(9):2655-62. doi: 10.1109/TBME.2013.2262150. Epub 2013 May 13. IEEE Trans Biomed Eng. 2013. PMID: 23674413
-
Development and implementation of an MR-compatible whole body video system.Neurosci Lett. 2007 Jun 13;420(2):122-7. doi: 10.1016/j.neulet.2007.03.063. Epub 2007 Apr 6. Neurosci Lett. 2007. PMID: 17532135
-
Respiration rate monitoring methods: a review.Pediatr Pulmonol. 2011 Jun;46(6):523-9. doi: 10.1002/ppul.21416. Epub 2011 Jan 31. Pediatr Pulmonol. 2011. PMID: 21560260 Review.
-
Thermal Cameras for Continuous and Contactless Respiration Monitoring.Sensors (Basel). 2024 Dec 19;24(24):8118. doi: 10.3390/s24248118. Sensors (Basel). 2024. PMID: 39771853 Free PMC article. Review.
Cited by
-
Towards Breathing as a Sensing Modality in Depth-Based Activity Recognition.Sensors (Basel). 2020 Jul 13;20(14):3884. doi: 10.3390/s20143884. Sensors (Basel). 2020. PMID: 32668594 Free PMC article.
-
Clinical validation of a contactless respiration rate monitor.Sci Rep. 2023 Mar 1;13(1):3480. doi: 10.1038/s41598-023-30171-4. Sci Rep. 2023. PMID: 36859403 Free PMC article.
-
Patient Posture Monitoring System Based on Flexible Sensors.Sensors (Basel). 2017 Mar 13;17(3):584. doi: 10.3390/s17030584. Sensors (Basel). 2017. PMID: 28335385 Free PMC article.
-
Context-Aware Medical Systems within Healthcare Environments: A Systematic Scoping Review to Identify Subdomains and Significant Medical Contexts.Int J Environ Res Public Health. 2023 Jul 19;20(14):6399. doi: 10.3390/ijerph20146399. Int J Environ Res Public Health. 2023. PMID: 37510631 Free PMC article.