Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Dec;55(6):716-23.
doi: 10.1111/j.1365-2559.2009.03427.x.

Chromogenic in situ hybridization for Her-2/neu-oncogene in breast cancer: comparison of a new dual-colour chromogenic in situ hybridization with immunohistochemistry and fluorescence in situ hybridization

Affiliations
Comparative Study

Chromogenic in situ hybridization for Her-2/neu-oncogene in breast cancer: comparison of a new dual-colour chromogenic in situ hybridization with immunohistochemistry and fluorescence in situ hybridization

Doris Mayr et al. Histopathology. 2009 Dec.

Abstract

Aims: Her-2/neu testing is used as a marker for Herceptin therapy. The aim was to investigate new dual-colour chromogenic in situ hybridization (CISH), in a large number of breast carcinomas (n = 205) with DNA-specific dual-colour probes (ZytoVision, Bremerhaven, Germany) and to compare the results with immunohistochemistry (n = 205) and fluorescence in situ hybridization (FISH) (n = 129).

Methods and results: Paraffin-embedded tissue of 205 patients was used. After immunohistochemistry with a focus on immunohistochemically uncertain cases, Her-2/neu amplification using dual-colour CISH (ZytoVision) was analysed. Validation by FISH was performed. The results were: immunohistochemistry, 27.8% with strong expression, 53.7% with uncertain overexpression and 18.5% with no expression; FISH, 25.6% amplified and 74.4% negative; CISH, 35.6% amplified, 62.9% negative and 1.5% not evaluable. Comparison of immunohistochemistry with CISH: CISH negative in 100% with immunohistochemistry 0/1+, amplified in 82.5% with immunohistochemistry 3+; 5.9% contradictory results: 4.4% immunohistochemistry 3+ and negative by CISH, 1.5% negative in immunohistochemistry but amplified by CISH; FISH (129 cases), 8.5% contradictory results to immunohistochemistry, 6.2% immunohistochemistry 3+ and negative by FISH, 2.3% negative by immunohistochemistry and amplified by FISH; comparison of CISH and FISH, 94.6% same results, 3.9% different ones, 1.6% CISH not analysable.

Conclusions: CISH, using dual-colour probes (ZytoVision) is as good as FISH for Her-2/neu analysis. The few discrepant results are likely to be caused by polysomy or tumour heterogeneity.

PubMed Disclaimer

Publication types