Metamaterial lens applicator for microwave hyperthermia of breast cancer
- PMID: 19925323
- DOI: 10.1080/02656730903061609
Metamaterial lens applicator for microwave hyperthermia of breast cancer
Abstract
Artificial left-handed metamaterial (LHM) provides a new perspective for microwave hyperthermia. Four flat LHM slab lenses can be used to form a focus-flexible applicator for breast tumour hyperthermia. By adjusting microwave sources behind the four flat LHM lenses, microwaves emitted from the sources can be focused tightly at different points in the breast tissue so that necessary heating depth in breast tissue can be achieved. Numerical simulations with a two-dimensional finite-difference time-domain method indicate that hyperthermia with the proposed four-lens applicator of moderate LHM losses could be effective in achieving desired power deposition in a heterogeneous breast model. Temperature distribution obtained by solving the bio-heat transfer equation demonstrates that temperature above 43 degrees C can be maintained in the tumour volume for specific periods of time. Flat slab LHM lenses offer a feasible alternative to traditional mechanically scanned lens applicator and electronically scanned phased-array applicators.
Similar articles
-
Conformal hyperthermia of superficial tumor with left-handed metamaterial lens applicator.IEEE Trans Biomed Eng. 2012 Dec;59(12):3525-30. doi: 10.1109/TBME.2012.2218108. Epub 2012 Sep 28. IEEE Trans Biomed Eng. 2012. PMID: 23033426
-
Computational feasibility of deformable mirror microwave hyperthermia technique for localized breast tumors.Int J Hyperthermia. 2007 Nov;23(7):577-89. doi: 10.1080/02656730701727484. Int J Hyperthermia. 2007. PMID: 18038288
-
Theoretical and experimental analysis of air cooling for intracavitary microwave hyperthermia applicators.IEEE Trans Biomed Eng. 1994 Sep;41(9):874-82. doi: 10.1109/10.312095. IEEE Trans Biomed Eng. 1994. PMID: 7959814
-
Conformal microwave array (CMA) applicators for hyperthermia of diffuse chest wall recurrence.Int J Hyperthermia. 2010;26(7):686-98. doi: 10.3109/02656736.2010.501511. Int J Hyperthermia. 2010. PMID: 20849262 Free PMC article. Review.
-
Thermal tumour ablation: devices, clinical applications and future directions.Int J Hyperthermia. 2005 Dec;21(8):755-60. doi: 10.1080/02656730500226423. Int J Hyperthermia. 2005. PMID: 16338858 Review.
Cited by
-
Advanced Radio Frequency Applicators for Thermal Magnetic Resonance Theranostics of Brain Tumors.Cancers (Basel). 2023 Apr 14;15(8):2303. doi: 10.3390/cancers15082303. Cancers (Basel). 2023. PMID: 37190232 Free PMC article.
-
Helmet Radio Frequency Phased Array Applicators Enhance Thermal Magnetic Resonance of Brain Tumors.Bioengineering (Basel). 2024 Jul 19;11(7):733. doi: 10.3390/bioengineering11070733. Bioengineering (Basel). 2024. PMID: 39061815 Free PMC article.
-
A Fully Phase-Modulated Metasurface as An Energy-Controllable Circular Polarization Router.Adv Sci (Weinh). 2020 Jul 16;7(18):2001437. doi: 10.1002/advs.202001437. eCollection 2020 Sep. Adv Sci (Weinh). 2020. PMID: 32999848 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical