Comparison of ELISA and SPR biosensor technology for the detection of paralytic shellfish poisoning toxins
- PMID: 19926541
- DOI: 10.1016/j.jchromb.2009.10.023
Comparison of ELISA and SPR biosensor technology for the detection of paralytic shellfish poisoning toxins
Abstract
An enzyme labeled immunosorbent assay (ELISA) and surface plasmon resonance (SPR) biosensor assay for the detection of paralytic shellfish poisoning (PSP) toxins were developed and a comparative evaluation was performed. A polyclonal antibody (BC67) used in both assay formats was raised to saxitoxin-jeffamine-BSA in New Zealand white rabbits. Each assay format was designed as an inhibition assay. Shellfish samples (n=54) were evaluated by each method using two simple rapid extraction procedures and compared to the AOAC high performance liquid chromatography (HPLC) and the mouse bioassay (MBA). The results of each assay format were comparable with the HPLC and MBA methods and demonstrate that an antibody with high sensitivity and broad specificity to PSP toxins can be applied to different immunological techniques. The method of choice will depend on the end-users needs. The reduced manual labor and simplicity of operation of the SPR biosensor compared to ELISA, ease of sample extraction and superior real time semi-quantitative analysis are key features that could make this technology applicable in a high-throughput monitoring unit.
Similar articles
-
Comparison of biosensor platforms for surface plasmon resonance based detection of paralytic shellfish toxins.Talanta. 2011 Jul 15;85(1):519-26. doi: 10.1016/j.talanta.2011.04.033. Epub 2011 Apr 17. Talanta. 2011. PMID: 21645735
-
Single laboratory validation of a surface plasmon resonance biosensor screening method for paralytic shellfish poisoning toxins.Anal Chem. 2010 Apr 1;82(7):2977-88. doi: 10.1021/ac1000338. Anal Chem. 2010. PMID: 20232817
-
Paralytic shellfish poisoning detection by surface plasmon resonance-based biosensors in shellfish matrixes.Anal Chem. 2007 Aug 15;79(16):6303-11. doi: 10.1021/ac070362q. Epub 2007 Jul 14. Anal Chem. 2007. PMID: 17630717
-
Paralytic shellfish poisoning (PSP) toxin binders for optical biosensor technology: problems and possibilities for the future: a review.Food Addit Contam Part A Chem Anal Control Expo Risk Assess. 2011 Jun;28(6):711-25. doi: 10.1080/19440049.2010.531198. Food Addit Contam Part A Chem Anal Control Expo Risk Assess. 2011. PMID: 21623494 Free PMC article. Review.
-
Immunoassay methods for paralytic shellfish poisoning toxins.J AOAC Int. 2001 Sep-Oct;84(5):1649-56. J AOAC Int. 2001. PMID: 11601488 Review.
Cited by
-
Determination of Cyanotoxins and Prymnesins in Water, Fish Tissue, and Other Matrices: A Review.Toxins (Basel). 2022 Mar 16;14(3):213. doi: 10.3390/toxins14030213. Toxins (Basel). 2022. PMID: 35324710 Free PMC article. Review.
-
Integrating scFv into xMAP Assays for the Detection of Marine Toxins.Toxins (Basel). 2016 Nov 21;8(11):346. doi: 10.3390/toxins8110346. Toxins (Basel). 2016. PMID: 27879646 Free PMC article.
-
Current Trends and Challenges for Rapid SMART Diagnostics at Point-of-Site Testing for Marine Toxins.Sensors (Basel). 2021 Apr 3;21(7):2499. doi: 10.3390/s21072499. Sensors (Basel). 2021. PMID: 33916687 Free PMC article. Review.
-
Paralytic shellfish poisoning due to ingestion of contaminated mussels: A 2018 case report in Caparica (Portugal).Toxicon X. 2019 Oct 1;4:100017. doi: 10.1016/j.toxcx.2019.100017. eCollection 2019 Oct. Toxicon X. 2019. PMID: 32550574 Free PMC article.
-
Clinical application of surface plasmon resonance-based biosensors for fetal fibronectin detection.Sensors (Basel). 2012;12(4):3879-90. doi: 10.3390/s120403879. Epub 2012 Mar 26. Sensors (Basel). 2012. PMID: 22666007 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous