. 2010 Feb;99(2):124-31.
doi: 10.1016/j.ymgme.2009.10.001. Epub 2009 Oct 12.

Validation of disaccharide compositions derived from dermatan sulfate and heparan sulfate in mucopolysaccharidoses and mucolipidoses II and III by tandem mass spectrometry

Affiliations

Validation of disaccharide compositions derived from dermatan sulfate and heparan sulfate in mucopolysaccharidoses and mucolipidoses II and III by tandem mass spectrometry

Shunji Tomatsu et al. Mol Genet Metab. 2010 Feb.

Abstract

Glycosaminoglycans (GAGs) are accumulated in various organs in both mucopolysaccharidoses (MPS) and mucolipidoses II and III (ML II and III). MPS and ML II and III patients can not properly degrade dermatan sulfate (DS) and/or heparan sulfate (HS). HS storage occurs in the brain leading to neurological signs while DS storage involves mainly visceral and skeletal manifestations. Excessive DS and HS released into circulation and thus blood levels of both are elevated, therefore, DS and HS in blood could be critical biomarkers for MPS and ML. Such measurement can provide a potential early screening, assessment of the clinical course and efficacy of therapies. We here assay DS and HS levels in MPS and ML patients using liquid chromatography tandem mass spectrometry (LC/MS/MS). Plasma samples were digested by heparitinase and chondroitinase B to obtain disaccharides of DS and HS, followed by LC/MS/MS analysis. One hundred-twenty samples from patients and 112 control samples were analyzed. We found that all MPS I, II, III and VI patients had a significant elevation of all DS+HS compositions analyzed in plasma, compared with the controls (P<0.0001). Specificity and sensitivity was 100% if the cut off value is 800 ng/ml between control and these types of MPS group. All MPS I, II and III patients also had a significant elevation of plasma HS, compared with the controls (P<0.0001). All MPS VI patients had a significant elevation of plasma DS, compared with the controls (P<0.0001). These findings suggest measurement of DS and/or HS levels by LC/MS/MS is applicable to the screening for MPS I, II, III and VI patients.