Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Dec;11(12):1458-66.
doi: 10.1093/ntr/ntp161. Epub 2009 Nov 23.

Interlaboratory comparability of serum cotinine measurements at smoker and nonsmoker concentration levels: a round-robin study

Affiliations
Comparative Study

Interlaboratory comparability of serum cotinine measurements at smoker and nonsmoker concentration levels: a round-robin study

John T Bernert et al. Nicotine Tob Res. 2009 Dec.

Abstract

Introduction: Cotinine, the primary proximate metabolite of nicotine, is commonly measured as an index of exposure to tobacco in both active users of tobacco and nonsmokers with possible exposure to secondhand smoke (SHS). A number of laboratories have implemented analyses for measuring serum cotinine in recent years, but there have been few interlaboratory comparisons of the results. Among nonsmokers exposed to SHS, the concentration of cotinine in blood can be quite low, and extensive variability in these measurements has been reported in the past.

Methods: In this study, a group of seven laboratories, all experienced in serum cotinine analysis, measured eight coded serum pools with concentrations ranging from background levels of about 0.05 ng/ml to relatively high concentrations in the active smokers range. All laboratories used either gas-liquid chromatography with nitrogen-phosphorus detection or liquid chromatography with mass spectrometric detection.

Results: All seven laboratories reliably measured the cotinine concentrations in samples that were within the range of their methods. In each case, the results for the pools were correctly ranked in order, and no significant interlaboratory bias was observed at the 5% level of significance for results from any of the pools.

Discussion: We conclude that present methods of chromatographic analysis of serum cotinine, as used by these experienced laboratories, are capable of providing accurate and precise results in both the smoker and the nonsmoker concentration range.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
Mandel’s h and k statistics.

References

    1. Benowitz NL. Cotinine as a biomarker of environmental tobacco smoke exposure. Epidemiological Review. 1996;18:188–204. - PubMed
    1. Benowitz NL, Bernert JT, Caraballo RS, Holiday DB, Wang J. Optimal serum cotinine levels for distinguishing cigarette smokers and nonsmokers within different racial/ethnic groups in the United States between 1999 and 2004. American Journal of Epidemiology. 2009;169:236–248. - PubMed
    1. Biber A, Scherer G, Hoepener H, Adlkofer F, Heller W, Haddow J, et al. Determination of nicotine and cotinine in human serum and urine: An interlaboratory study. Toxicology Letters. 1987;35:45–52. - PubMed
    1. Borland R, Mullins R, Trotter L, White V. Trends in environmental tobacco smoke restrictions in the home in Victoria, Australia. Tobacco Control. 1999;8:266–271. - PMC - PubMed
    1. Centers for Disease Control and Prevention. Cigarette smoking among adults—United States, 2006. Morbidity and Mortality Weekly Report. 2007 [serial online], 56, 1157–1161. Retrieved 8 November 2007, from http://www.cdc.gov/mmwr/preview/mmwrhtml/mm5644a2.htm. - PubMed

Publication types

MeSH terms