. 2010 Apr;52(4):275-83.
doi: 10.1007/s00234-009-0623-7.

Magnetic resonance plaque imaging to predict the occurrence of the slow-flow phenomenon in carotid artery stenting procedures

Affiliations

Magnetic resonance plaque imaging to predict the occurrence of the slow-flow phenomenon in carotid artery stenting procedures

Masahiko Sakamoto et al. Neuroradiology. 2010 Apr.

Abstract

Introduction: The purpose is to investigate the feasibility of magnetic resonance (MR) plaque imaging in predicting the arterial flow impairment (slow-flow phenomenon) during carotid artery stenting (CAS) using a filter-type protection device.

Methods: Thirty-one carotid artery stenotic lesions in 30 patients (28 men and two women; mean age, 71.8 years) were evaluated by MR plaque imaging with black blood T1- and T2-weighted and time-of-flight sequences before CAS. Main plaque components were classified as vulnerable (intraplaque hemorrhage and lipid-rich/necrotic core) or stable (fibrous tissue and dense calcification) from the signal pattern. The plaque classification was statistically compared with the occurrence of slow-flow phenomenon.

Results: The slow-flow phenomenon was observed in ten CAS procedures (five flow arrests and five flow reductions). Flow arrests consisted of four vulnerable and one stable plaque, and flow reductions consisted of four vulnerable and one stable plaque. The slow-flow phenomenon occurred significantly (P<0.01) more frequently in patients with vulnerable plaque.

Conclusions: Vulnerable carotid plaques have a significantly higher risk of slow-flow phenomenon than stable plaques. The occurrence of the slow-flow phenomenon can be predicted by MR plaque imaging before CAS.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Br J Surg. 2001 Jul;88(7):945-50 - PubMed
    1. Catheter Cardiovasc Interv. 2007 Aug 1;70(2):316-23 - PubMed
    1. J Pathol. 1999 Jun;188(2):189-96 - PubMed
    1. AJNR Am J Neuroradiol. 2008 Mar;29(3):608-12 - PubMed
    1. J Endovasc Ther. 2007 Oct;14(5):712-24 - PubMed

LinkOut - more resources