A randomized double-blind crossover comparison of four rate-responsive pacing modes
- PMID: 1993790
- DOI: 10.1016/s0735-1097(10)80186-x
A randomized double-blind crossover comparison of four rate-responsive pacing modes
Abstract
The aim of this study was to compare, both subjectively and objectively, four modern rate-responsive pacing modes in a double-blind crossover design. Twenty-two patients, aged 18 to 81 years, had an activity-sensing dual chamber universal rate-responsive (DDDR) pacemaker implanted for treatment of high grade atrioventricular block and chronotropic incompetence. They were randomly programmed to VVIR (ventricular demand rate-responsive), DDIR (dual chamber demand rate-responsive), DDD (dual chamber universal) or DDDR (dual chamber universal rate-responsive) mode and assessed after 4 weeks of out-of-hospital activity. Five patients, all with VVIR pacing, requested early reprogramming. The DDDR mode was preferred by 59% of patients; the VVIR mode was the least acceptable mode in 73%. Perceived "general well-being," exercise capacity, functional status and symptoms were significantly worse in the VVIR than in dual rate-responsive modes. Exercise treadmill time was longer in DDDR mode (p less than 0.01), but similar in all other modes. During standardized daily activities, heart rate in VVIR and DDIR modes underresponded to mental stress. All rate-augmented modes overresponded to staircase descent, whereas the DDD mode significantly underresponded to staircase ascent. Echocardiography revealed no difference in chamber dimensions, left ventricular fractional shortening or pulmonary artery pressure in any mode. Cardiac output was greater at rest in the dual modes than in the VVIR mode (p = 0.006) but was similar at 120 beats/min. Beat to beat variability of cardiac output was greatest in VVIR mode (p less than 0.0001), with DDIR showing greater variability than DDD or DDDR modes (p less than 0.05). Mitral regurgitation estimated by Doppler color flow imaging was similar in all modes, but tricuspid regurgitation was significantly greater in VVIR than in dual modes (p less than 0.03). Subjects who preferred the DDDR mode and those who found the VVIR mode least acceptable had significantly greater increases in stroke volume when paced in the DDD mode than in the ventricular-inhibited (VVI) mode at rest (22%) when compared with subjects who preferred other modes (2%, p = 0.03). No other objective variable was predictive of subjective benefit from any rate-responsive pacing mode. Thus, dual sensor rate-responsive pacing (DDDR) is superior objectively and subjectively to single sensor (VVIR, DDIR and DDD) pacing and subjective benefit from dual chamber rate-augmented pacing is predictable echocardiographically.
Similar articles
-
Superior cardiac hemodynamics of atrioventricular synchrony over rate responsive pacing at submaximal exercise: observations in activity sensing DDDR pacemakers.Pacing Clin Electrophysiol. 1990 Dec;13(12 Pt 2):1832-7. doi: 10.1111/j.1540-8159.1990.tb06899.x. Pacing Clin Electrophysiol. 1990. PMID: 1704550 Clinical Trial.
-
[An intrapatient comparison of adaptation to aerobic and anaerobic exertion during 3 types of physiological cardiac stimulation in chronotropic failure of the sinus node: DDD, VVIR and DDDR].Cardiologia. 1997 Jan;42(1):51-7. Cardiologia. 1997. PMID: 9118155 Clinical Trial. Italian.
-
Rate adaptive pacing in sick sinus syndrome: effects of pacing modes and intrinsic conduction on physiological responses, arrhythmias, symptomatology and quality of life.Eur Heart J. 1994 Nov;15(11):1445-55. doi: 10.1093/oxfordjournals.eurheartj.a060413. Eur Heart J. 1994. PMID: 7835358 Clinical Trial.
-
Efficacy and safety of rate responsive pacing in patients with coronary artery disease and angina pectoris.Pacing Clin Electrophysiol. 1989 Aug;12(8):1405-11. doi: 10.1111/j.1540-8159.1989.tb05055.x. Pacing Clin Electrophysiol. 1989. PMID: 2476765 Review.
-
Pacemaker hemodynamics: clinical implications.Prog Cardiovasc Dis. 1992 Mar-Apr;34(5):347-66. doi: 10.1016/0033-0620(92)90039-3. Prog Cardiovasc Dis. 1992. PMID: 1542730 Review.
Cited by
-
Effects of cardiac pacemakers on left ventricular volumes and function assessed by 3D echocardiography, Doppler method, and global longitudinal strain.Egypt Heart J. 2021 Feb 22;73(1):16. doi: 10.1186/s43044-021-00138-9. Egypt Heart J. 2021. PMID: 33616794 Free PMC article.
-
Effect of rate-adaptive pacing on performance and physiological parameters during activities of daily living in the elderly: results from the CLEAR (Cylos Responds with Physiologic Rate Changes during Daily Activities) study.Europace. 2013 Jun;15(6):849-56. doi: 10.1093/europace/eus425. Epub 2013 Feb 17. Europace. 2013. PMID: 23419655 Free PMC article. Clinical Trial.
-
"Subclinical" pacemaker syndrome: a randomised study of symptom free patients with ventricular demand (VVI) pacemakers upgraded to dual chamber devices.Br Heart J. 1992 Jan;67(1):57-64. doi: 10.1136/hrt.67.1.57. Br Heart J. 1992. PMID: 1739528 Free PMC article. Clinical Trial.
-
Brazilian Guidelines for Cardiac Implantable Electronic Devices - 2023.Arq Bras Cardiol. 2023 Jan 23;120(1):e20220892. doi: 10.36660/abc.20220892. Arq Bras Cardiol. 2023. PMID: 36700596 Free PMC article. English, Portuguese. No abstract available.
-
Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function.Eur J Nucl Med Mol Imaging. 2005 Sep;32(9):1075-80. doi: 10.1007/s00259-005-1790-3. Epub 2005 May 13. Eur J Nucl Med Mol Imaging. 2005. PMID: 15891919 Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials