Gadolinium-based contrast agents and nephrogenic systemic fibrosis: why did it happen and what have we learned?
- PMID: 19938035
- DOI: 10.1002/jmri.21979
Gadolinium-based contrast agents and nephrogenic systemic fibrosis: why did it happen and what have we learned?
Abstract
This article addresses two questions about gadolinium-based contrast agents (GBCAs) and nephrogenic systemic fibrosis (NSF): "Why did it happen" and "What have we learned"? It reviews the events leading to the discovery of an association between NSF and GBCAs. Various factors are elucidated that contributed to the delay between the time when GBCA came into widespread clinical use and a link was made with NSF, including use in renal-compromised patients, high-dose magnetic resonance angiography (MRA), lack of documentation and adequate databases, policy and regulatory changes, and an absence of scientific evidence. The authors conclude that the overriding cause was lack of awareness. J. Magn. Reson. Imaging 2009;30:1236-1239. (c) 2009 Wiley-Liss, Inc.
Similar articles
-
Gadolinium-based contrast agents and NSF: evidence from animal experience.J Magn Reson Imaging. 2009 Dec;30(6):1268-76. doi: 10.1002/jmri.21971. J Magn Reson Imaging. 2009. PMID: 19938039 Review.
-
Nephrogenic systemic fibrosis.Magn Reson Imaging Clin N Am. 2009 Feb;17(1):159-67. doi: 10.1016/j.mric.2009.01.003. Magn Reson Imaging Clin N Am. 2009. PMID: 19364606 Review.
-
Nephrogenic systemic fibrosis: clinical spectrum of disease.J Magn Reson Imaging. 2009 Dec;30(6):1289-97. doi: 10.1002/jmri.21975. J Magn Reson Imaging. 2009. PMID: 19937929 Review.
-
Mechanism of NSF: New evidence challenging the prevailing theory.J Magn Reson Imaging. 2009 Dec;30(6):1277-83. doi: 10.1002/jmri.21980. J Magn Reson Imaging. 2009. PMID: 19937925
-
Nephrogenic systemic fibrosis and its impact on abdominal imaging.Radiographics. 2009 Oct;29(6):1565-74. doi: 10.1148/rg.296095517. Radiographics. 2009. PMID: 19959508 Review.
Cited by
-
Noncontrast peripheral MRA with spiral echo train imaging.Magn Reson Med. 2015 Mar;73(3):1026-33. doi: 10.1002/mrm.25216. Epub 2014 Apr 17. Magn Reson Med. 2015. PMID: 24753164 Free PMC article.
-
In vivo detection of oxidation-specific epitopes in atherosclerotic lesions using biocompatible manganese molecular magnetic imaging probes.J Am Coll Cardiol. 2012 Feb 7;59(6):616-26. doi: 10.1016/j.jacc.2011.10.881. J Am Coll Cardiol. 2012. PMID: 22300697 Free PMC article.
-
Reperfusion injury components and manifestations determined by cardiovascular MR and MDCT imaging.World J Radiol. 2010 Jan 28;2(1):1-14. doi: 10.4329/wjr.v2.i1.1. World J Radiol. 2010. PMID: 21160735 Free PMC article.
-
Comparison of ferumoxytol-based cerebral blood volume estimates using quantitative R1 and R2* relaxometry.Magn Reson Med. 2018 Jun;79(6):3072-3081. doi: 10.1002/mrm.26975. Epub 2017 Nov 2. Magn Reson Med. 2018. PMID: 29096054 Free PMC article.
-
Are Gadolinium-Enhanced MR Sequences Needed in Simultaneous 18F-FDG-PET/MRI for Tumor Delineation in Head and Neck Cancer?AJNR Am J Neuroradiol. 2020 Oct;41(10):1888-1896. doi: 10.3174/ajnr.A6764. Epub 2020 Sep 24. AJNR Am J Neuroradiol. 2020. PMID: 32972956 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical