Fetal scalp lactate microsampling for non-reassuring fetal status during labor: a prospective observational study
- PMID: 19940450
- DOI: 10.1159/000262281
Fetal scalp lactate microsampling for non-reassuring fetal status during labor: a prospective observational study
Abstract
Objective: The aim was to study the predictive value and feasibility of fetal scalp lactate microsampling in the management of non-reassuring fetal status during labor.
Methods: A prospective observational study was conducted on cord blood gas samplings from 7,617 singleton and cephalic deliveries at > or =37 weeks of gestation. In this population, 450 fetal scalp blood samples (FBS) were performed for abnormal fetal heart rate (FHR) patterns. Microvolume scalp lactate measurements were compared to scalp pH, neonatal cord blood gas parameters (pH, lactate, base deficit) and the Apgar score.
Results: Scalp lactate correlated significantly with scalp pH (r = -0.56, p = 0.001), umbilical artery pH (r = -0.39, p = 0.03), umbilical artery lactate (r = 0.48, p = 0.01) and umbilical artery base deficit (r = 0.51, p = 0.01), but not with Apgar scores. Using receiver operating characteristic curves, a scalp lactate cutoff value of 5 mmol/l was the most predictive for neonatal acidosis. Sampling failure with scalp lactate was inferior to scalp pH (1.3 vs. 14%, p < 0.001).
Conclusion: Lactate microsampling in fetal scalp blood was found to be an attractive alternative to pH analysis and a useful 2nd-line tool for monitoring fetal asphyxia during labor.
Copyright 2009 S. Karger AG, Basel.
Similar articles
-
[Value of fetal scalp lactate sampling during labour: a comparative study with scalp pH].Gynecol Obstet Fertil. 2005 Mar;33(3):107-12. doi: 10.1016/j.gyobfe.2005.01.004. Gynecol Obstet Fertil. 2005. PMID: 15848081 French.
-
[Interest of lactate micro-dosage in scalp and umbilical cord in cases of abnormal fetal heart rate during labor. Prospective study on 162 patients].J Gynecol Obstet Biol Reprod (Paris). 2012 Jun;41(4):324-32. doi: 10.1016/j.jgyn.2011.11.002. Epub 2011 Dec 15. J Gynecol Obstet Biol Reprod (Paris). 2012. PMID: 22177756 French.
-
Scalp blood lactate for intra-partum assessment of fetal metabolic acidosis.Acta Obstet Gynecol Scand. 2011 Oct;90(10):1107-14. doi: 10.1111/j.1600-0412.2011.01237.x. Epub 2011 Aug 29. Acta Obstet Gynecol Scand. 2011. PMID: 21751970
-
[Fetal scalp blood sampling for pH and lactate measurement during labour].J Gynecol Obstet Biol Reprod (Paris). 2008 Feb;37 Suppl 1:S65-71. doi: 10.1016/j.jgyn.2007.11.012. Epub 2008 Jan 7. J Gynecol Obstet Biol Reprod (Paris). 2008. PMID: 18179877 Review. French.
-
[Rapid microanalysis of lactate in cord blood and at fetal scalp blood sampling].Gynecol Obstet Fertil. 2004 Mar;32(3):241-4. doi: 10.1016/j.gyobfe.2004.01.010. Gynecol Obstet Fertil. 2004. PMID: 15123123 Review. French.
Cited by
-
A new microdialysis probe for continuous lactate measurement during fetal monitoring: Proof of concept in an animal model.Acta Obstet Gynecol Scand. 2020 Oct;99(10):1411-1416. doi: 10.1111/aogs.13865. Epub 2020 Apr 21. Acta Obstet Gynecol Scand. 2020. PMID: 32274792 Free PMC article.
-
Infant outcome at four years of age after intrapartum sampling of scalp blood lactate for fetal assessment. A cohort study.PLoS One. 2018 Mar 23;13(3):e0193887. doi: 10.1371/journal.pone.0193887. eCollection 2018. PLoS One. 2018. PMID: 29570701 Free PMC article.
-
Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace.Cochrane Database Syst Rev. 2015 May 1;2015(5):CD006174. doi: 10.1002/14651858.CD006174.pub3. Cochrane Database Syst Rev. 2015. PMID: 25929461 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources